User friendly
Color Touch Panel for good usability 7 inch color touchscreen with high operability displays measurement results, instrument conditions and operating instructions.
“Sample delivery system” enables micro volume samples to be measured
As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume.
Specification
Measurement object | Urine |
---|---|
Reagent | AUTION Sticks/ Uriflet S |
Measurement items | GLU (Glucose), PRO (Protein), BIL (Bilirubin), URO(Urobilinogen), PH (pH), BLD (Blood), KET (Ketones),NIT (Nitrite), LEU (Leukocytes), CRE (Creatinine), ALB(Microalbumin), P/C (Ratio of Protein to Creatinine),A/C (Ratio of Albumin to Creatinine), S.G. (Specific gravity),turbidity and color tone |
Measurement range | Test strip: For rank table, see page 1-12. S.G.: 1.000 to 1.050(Resolution: 0.001) Color tone: For color classification diagram, see page 1-10. Turbidity: Three levels including “clear”, “turbid” and “dense turbid” |
Measurement principle | Test strip: Dual-wavelength reflectance measurement (Single wavelength for BLD) S.G.: Reflection refractometry Color tone: Light-transmission measurement Turbidity:Light-scattering measurement |
Measurement wavelength | 5 LED wavelengths (450, 525, 562, 635 and 760 nm) |
Test strip reaction time | Approximately 60 seconds |
Test strip storage | Two test strip storage compartments, each of which can contain different test strips |
Test strip storage capacity | Maximum 200 test strips x two storage compartments |
Processing speed | Normal measurement: Maximum 225 samples/hour Small volume measurement: Maximum 112 samples/hour |
Required sample volume | Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL |
Sample container | Sample tubes (length: 95 – 110 mm, diameter: 014.0 – 15.8 mm) |
Sample loading capacity | One-way transportation (default): Maximum 50 samples Loop transportation: Maximum 100 samples |
Warm-up time | Maximum 4 minutes |
Display | Large color liquid crystal display (800 × 480 dots) |
Built-in printer | 58-mm width printer paper (24 digits) |
Memory capacity | Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests |
External output | 1 port (Replaceable with the optional Ethernet terminal) |
Communication system | RS-232C compliant (Switchable between one-way and two-way) |
Transmission speed | RS-232C: Selectable from 300, 600, 1200, 2400, 4800,9600 and 19200 bps Ethernet: 10BASE-T |
Measurement environment | Temperature: 10 – 30°C Humidity: 30 – 60% RH (No condensation) |
Dimensions | 530(W) × 530(D)× 530(H) mm(including the sampler) |
Weight | Main body: Approximately 40 kg Sampler: Approximately 4 kg |
Power requirements | 100 – 240 V AC (Maximum power line fluctuation of±10%) 50/60 Hz |
Power input | Maximum 150 VA |