{"id":7270,"date":"2021-11-27T04:52:20","date_gmt":"2021-11-27T04:52:20","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7270"},"modified":"2021-11-27T04:54:01","modified_gmt":"2021-11-27T04:54:01","slug":"incubator-if260","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/nl\/product\/incubator-if260\/","title":{"rendered":"Broedmachine IF260"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temperatuur<\/h4>\n\n\n\n\n\n\n
Temperatuurbereik instellen:<\/th>\n+20 tot +80 \u00b0C<\/td>\n<\/tr>\n
Werktemperatuurbereik:<\/th>\nmin. 10\u00b0C boven omgevingstemperatuur tot +80\u00b0C<\/td>\n<\/tr>\n
Nauwkeurigheidstemperatuur instellen:<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Temperatuursensor<\/th>\n1 Pt100 sensor DIN klasse A in 4-draads circuit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Besturingstechnologie<\/h4>\n\n\n\n\n\n\n\n\n
Taalinstelling<\/th>\nDuits, Engels, Spaans, Frans, Pools, Tsjechisch, Hongaars<\/td>\n<\/tr>\n
ControleCOCKPIT<\/th>\nEnkele DISPLAY. Adaptieve multifunctionele digitale PID-microprocessorcontroller met high-definition TFT-kleurendisplay<\/td>\n<\/tr>\n
Timer<\/th>\nDigitale achterwaartse teller met doeltijdinstelling, instelbaar van 1 minuut tot 99 dagen<\/td>\n<\/tr>\n
Functie SetpointWAIT<\/th>\nde procestijd begint pas als de ingestelde temperatuur is bereikt<\/td>\n<\/tr>\n
Kalibratie<\/th>\ndrie vrij te kiezen temperatuurwaarden<\/td>\n<\/tr>\n
instelbare parameters:<\/th>\ntemperatuur (Celsius of Fahrenheit), ventilatorsnelheid, luchtklepstand, programmatijd, tijdzones, zomer-\/wintertijd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilatie<\/h4>\n\n\n\n\n\n
Fan<\/th>\ngeforceerde luchtcirculatie door stille luchtturbine, instelbaar in 10 %-stappen<\/td>\n<\/tr>\n
Verse lucht<\/th>\nBijmenging van voorverwarmde verse lucht door elektronisch verstelbare luchtklep<\/td>\n<\/tr>\n
ontluchten<\/th>\nontluchtingsaansluiting met restrictieklep<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Communicatie<\/h4>\n\n\n\n\n
Documentatie<\/th>\nprogramma opgeslagen in geval van stroomuitval<\/td>\n<\/tr>\n
Programmeren<\/th>\nAtmoCONTROL-software voor het uitlezen, beheren en organiseren van de datalogger via Ethernet-interface (tijdelijke proefversie kan worden gedownload). USB-stick met AtmoCONTROL-software als accessoire verkrijgbaar (op aanvraag).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Veiligheid<\/h4>\n\n\n\n\n
Temperatuurregeling<\/th>\ninstelbare elektronische oververhittingsbewaking en mechanische temperatuurbegrenzer TB, beschermingsklasse 1 volgens DIN 12880 voor het uitschakelen van de verwarming ca. 20\u00b0C boven nominale temperatuur<\/td>\n<\/tr>\n
Autodiagnostisch systeem<\/th>\nvoor foutanalyse<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Standaard uitrusting<\/h4>\n\n\n\n\n\n\n
Deur<\/th>\nvolledig ge\u00efsoleerde RVS deur met 2-punts vergrendeling (drukdeurslot)<\/td>\n<\/tr>\n
binnenwerk<\/th>\n2 roestvrijstalen rooster(s), elektrolytisch gepolijst<\/td>\n<\/tr>\n
Werkkalibratiecertificaat<\/th>\nincl. fabriekskalibratiecertificaat voor +37\u00b0C<\/td>\n<\/tr>\n
Deur<\/th>\nglazen binnendeur:<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

RVS interieur<\/h4>\n\n\n\n\n\n\n\n\n
Dimensies<\/th>\nmet wie(EEN)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 640 x 800 x 500 mm (d minus 39 mm voor ventilator)<\/td>\n<\/tr>\n
Interieur<\/th>\ngemakkelijk te reinigen binnenkant, van roestvrij staal, versterkt door diepgetrokken ribbels met ge\u00efntegreerde en beschermde grootvlakverwarming aan vier zijden<\/td>\n<\/tr>\n
Volume<\/th>\n256 l<\/td>\n<\/tr>\n
Maximaal aantal internals<\/th>\n9<\/td>\n<\/tr>\n
Maximaal laden van kamer<\/th>\n300 kg<\/td>\n<\/tr>\n
Maximaal laden per intern<\/th>\n20 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Getextureerde roestvrijstalen behuizing<\/h4>\n\n\n\n\n
Dimensies<\/th>\nmet wie(D)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 824 x 1183 x 684 mm (d +56 mm deurkruk)<\/td>\n<\/tr>\n
huisvesting<\/th>\nachter verzinkt staal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Elektrische data<\/h4>\n\n\n\n\n
Spanning Elektrische belasting:<\/th>\n230 V, 50\/60 Hz
\nca. 1700 W<\/td>\n<\/tr>\n
Spanning Elektrische belasting:<\/th>\n115 V, 50\/60 Hz
\nca. 900 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Omgevingscondities<\/h4>\n\n\n\n\n\n\n\n\n
Opgericht<\/th>\nDe afstand tussen de muur en de achterkant van het apparaat moet minimaal 15 cm zijn. De afstand tot het plafond mag niet minder zijn dan 20 cm en de afstand vanaf de zijkant tot muren of nabije apparaten mag niet minder zijn dan 5 cm.<\/td>\n<\/tr>\n
Hoogte van installatie<\/th>\nmaximaal 2000 m boven zeeniveau<\/td>\n<\/tr>\n
Omgevingstemperatuur<\/th>\n+5 \u00b0C tot +40 \u00b0C<\/td>\n<\/tr>\n
Vochtigheid rh<\/th>\nmaximaal 80 %, niet-condenserend<\/td>\n<\/tr>\n
Overspanningscategorie<\/th>\nII<\/td>\n<\/tr>\n
Vervuilingsgraad<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":7271,"template":"","meta":{"nf_dc_page":""},"product_cat":[110],"product_tag":[],"class_list":{"0":"post-7270","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-compressor-cooled-incubator","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"\nIncubator IF260 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/incubator-if260\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Incubator IF260\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range min. 10\u00b0C above ambient up to +80\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 1 Pt100 sensor DIN class A in 4-wire-circuit Control technology Language setting German, English, Spanish, French, Polish, Czech, Hungarian ControlCOCKPIT SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime\/wintertime Ventilation Fan forced air circulation by quiet air turbine, adjustable in 10\u00a0% steps Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Autodiagnostic system for fault analysis Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 39 mm for fan) Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 300\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 684\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1700\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 900\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/incubator-if260\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-27T04:54:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"412\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/\",\"name\":\"Incubator IF260 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1\",\"datePublished\":\"2021-11-27T04:52:20+00:00\",\"dateModified\":\"2021-11-27T04:54:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1\",\"width\":480,\"height\":412,\"caption\":\"Incubator IF260\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Incubator IF260\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Incubator IF260 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/nl\/product\/incubator-if260\/","og_locale":"nl_NL","og_type":"article","og_title":"Incubator IF260","og_description":"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range min. 10\u00b0C above ambient up to +80\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 1 Pt100 sensor DIN class A in 4-wire-circuit Control technology Language setting German, English, Spanish, French, Polish, Czech, Hungarian ControlCOCKPIT SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime\/wintertime Ventilation Fan forced air circulation by quiet air turbine, adjustable in 10\u00a0% steps Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Autodiagnostic system for fault analysis Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 39 mm for fan) Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 300\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 684\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1700\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 900\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/nl\/product\/incubator-if260\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-27T04:54:01+00:00","og_image":[{"width":480,"height":412,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/","url":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/","name":"Incubator IF260 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1","datePublished":"2021-11-27T04:52:20+00:00","dateModified":"2021-11-27T04:54:01+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IF260.png?fit=480%2C412&ssl=1","width":480,"height":412,"caption":"Incubator IF260"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-if260\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Incubator IF260"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product\/7270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media\/7271"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media?parent=7270"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_cat?post=7270"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_tag?post=7270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}