{"id":6962,"date":"2021-11-16T12:41:30","date_gmt":"2021-11-16T12:41:30","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&#038;p=6962"},"modified":"2021-11-16T12:47:26","modified_gmt":"2021-11-16T12:47:26","slug":"peltier-cooled-incubator-ipp750ecoplus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp750ecoplus\/","title":{"rendered":"Peltier-gekoelde broedstoof IPP750ecoplus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<h4>Temperatuur<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Temperatuurbereik instellen:<\/th>\n<td colspan=\"1\">0 tot +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Werktemperatuurbereik:<\/th>\n<td colspan=\"1\">met licht: +10 tot +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Werktemperatuurbereik:<\/th>\n<td colspan=\"1\">zonder licht: van 0 (minstens 20 onder de omgevingstemperatuur) tot +70\u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Nauwkeurigheidstemperatuur instellen:<\/th>\n<td colspan=\"1\">0,1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Temperatuursensor<\/th>\n<td colspan=\"1\">2 Pt100-sensoren DIN Klasse A in 4-draads circuit voor onderlinge bewaking, functies overnemen in geval van storing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Besturingstechnologie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">ControleCOCKPIT<\/th>\n<td colspan=\"1\">TwinDISPLAY. Adaptieve multifunctionele digitale PID-microprocessorcontroller met 2 high-definition TFT-kleurendisplays.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Taalinstelling<\/th>\n<td colspan=\"1\">Duits, Engels, Spaans, Frans, Pools, Tsjechisch, Hongaars<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Timer<\/th>\n<td colspan=\"1\">Digitale achterwaartse teller met doeltijdinstelling, instelbaar van 1 minuut tot 99 dagen<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Functie HeatBALANCE<\/th>\n<td colspan=\"1\">de verdeling van het verwarmingsvermogen van het bovenste en onderste verwarmingscircuit aanpassen van -50 % tot +50 %<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Functie SetpointWAIT<\/th>\n<td colspan=\"1\">de procestijd begint pas als de ingestelde temperatuur is bereikt<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Kalibratie<\/th>\n<td colspan=\"1\">drie vrij te kiezen temperatuurwaarden<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">instelbare parameters:<\/th>\n<td colspan=\"1\">temperatuur (Celsius of Fahrenheit), programmatijd, tijdzones, zomertijd\/wintertijd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Ventilatie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Convectie<\/th>\n<td colspan=\"1\">geforceerde ventilatie door Peltier-ventilator<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Communicatie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Documentatie<\/th>\n<td colspan=\"1\">programma opgeslagen in geval van stroomuitval<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Programmeren<\/th>\n<td colspan=\"1\">AtmoCONTROL-software op USB-stick voor het programmeren, beheren en overdragen van programma&#039;s via Ethernet-interface of USB-poort<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Veiligheid<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Temperatuurregeling<\/th>\n<td colspan=\"1\">over- en ondertemperatuurbewaking TWW, beschermingsklasse 3.3 of instelbare temperatuurbegrenzer TWB, beschermingsklasse 2, selecteerbaar op display<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">AutoVEILIGHEID<\/th>\n<td colspan=\"1\">extra ge\u00efntegreerde over- en ondertemperatuurbeveiliging &quot;ASF&quot;, automatisch volgen van de gewenste waarde in een vooraf ingesteld tolerantiebereik, alarm bij over- of ondertemperatuur, verwarmingsfunctie wordt uitgeschakeld bij te hoge temperatuur, koelfunctie bij te lage temperatuur<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Autodiagnostisch systeem<\/th>\n<td colspan=\"1\">voor foutanalyse<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Alarm<\/th>\n<td colspan=\"1\">visueel en akoestisch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Verwarmingsconcept<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Peltier<\/th>\n<td colspan=\"1\">Verdeling van verwarmings- en koelprestaties door individuele regeling van de Peltier-elementen in de bovenste en onderste rij<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Peltier<\/th>\n<td colspan=\"1\">energiebesparend Peltier verwarmings-\/koelsysteem ge\u00efntegreerd in de achterzijde (warmtepompprincipe)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Standaard uitrusting<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">binnenwerk<\/th>\n<td colspan=\"1\">2 roestvrijstalen rooster(s), elektrolytisch gepolijst<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Werkkalibratiecertificaat<\/th>\n<td colspan=\"1\">voor +10\u00b0C en +37\u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Deur<\/th>\n<td colspan=\"1\">glazen binnendeuren<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Deur<\/th>\n<td colspan=\"1\">volledig ge\u00efsoleerde RVS deuren met 2-punts vergrendeling (drukdeurslot)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>RVS interieur<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Dimensies<\/th>\n<td colspan=\"1\">met wie<sub>(EEN)<\/sub>\u00a0xh<sub>(B)<\/sub>\u00a0xd<sub>(C)<\/sub>: 1040 x 1200 x 600 mm (d minus 32 mm voor ventilator \u2013 Peltier)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Volume<\/th>\n<td colspan=\"1\">749 l<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal aantal internals<\/th>\n<td colspan=\"1\">14<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal laden van kamer<\/th>\n<td colspan=\"1\">200 kg<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal laden per intern<\/th>\n<td colspan=\"1\">30 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Getextureerde roestvrijstalen behuizing<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Dimensies<\/th>\n<td colspan=\"1\">met wie<sub>(D)<\/sub>\u00a0xh<sub>(E)<\/sub>\u00a0xd<sub>(F)<\/sub>: 1224 x 1720 x 755 mm (d +56mm deurkruk &amp; +111mm Peltier element)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Installatie<\/th>\n<td colspan=\"1\">op vergrendelbare wielen<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">huisvesting<\/th>\n<td colspan=\"1\">achter verzinkt staal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Elektrische data<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Spanning Elektrische belasting:<\/th>\n<td colspan=\"1\">230 V, 50\/60 Hz<br \/>\nca. 1300 W<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Spanning Elektrische belasting:<\/th>\n<td colspan=\"1\">115 V, 50\/60 Hz<br \/>\nca. 1300 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Omgevingscondities<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Opgericht<\/th>\n<td colspan=\"1\">De afstand tussen de muur en de achterkant van het apparaat moet minimaal 15 cm zijn. De afstand tot het plafond mag niet minder zijn dan 20 cm en de afstand vanaf de zijkant tot muren of nabije apparaten mag niet minder zijn dan 5 cm.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Omgevingstemperatuur<\/th>\n<td colspan=\"1\">16 \u00baC tot 40 \u00baC<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Vochtigheid rh<\/th>\n<td colspan=\"1\">maximaal 70 %, niet-condenserend<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Hoogte van installatie<\/th>\n<td colspan=\"1\">maximaal 2000 m boven zeeniveau<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Overspanningscategorie<\/th>\n<td colspan=\"1\">II<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Vervuilingsgraad<\/th>\n<td colspan=\"1\">2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6963,"template":"","meta":{"nf_dc_page":""},"product_brand":[],"product_cat":[91],"product_tag":[],"class_list":{"0":"post-6962","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-peltier-cooled-incubator","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.9 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp750ecoplus\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP750ecoplus\" \/>\n<meta property=\"og:description\" content=\"Temperature    Setting temperature range 0 to +70 \u00b0C   Working temperature range with light: +10 to +40 \u00b0C   Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C   Setting accuracy temperature 0.1 \u00b0C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days   Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0%   Function SetpointWAIT the process time does not start until the set temperature is reached   Calibration three freely selectable temperature values   adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime    Ventilation    Convection forced ventilation by Peltier fan    Communication    Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display   AutoSAFETY additionally integrated over- and undertemperature protection &quot;ASF&quot;, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system for fault analysis   Alarm visual and acoustic    Heating concept    Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row   Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle)    Standard equipment    Internals 2 stainless steel grid(s), electropolished   Works calibration certificate for +10\u00b0C and +37\u00b0C   Door inner glass doors   Door fully insulated stainless steel doors with 2-point locking (compression door lock)    Stainless steel interior    Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 1200 x 600\u00a0mm (d less 32 mm for fan - Peltier)   Volume 749\u00a0l   Max. number of internals 14   Max. loading of chamber 200\u00a0kg   Max. loading per internal 30 kg    Textured stainless steel casing    Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1720 x 755\u00a0mm (d +56mm door handle &amp; +111mm Peltier element)   Installation on lockable castors   Housing rear zinc-plated steel    Electrical data    Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W   Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W    Ambient conditions    Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.   Ambient temperature 16 \u00baC to 40 \u00baC   Humidity rh max. 70 %, non-condensing   Altitude of installation max. 2,000 m above sea level   Overvoltage category II   Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp750ecoplus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T12:47:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"493\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/\",\"name\":\"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"datePublished\":\"2021-11-16T12:41:30+00:00\",\"dateModified\":\"2021-11-16T12:47:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"width\":480,\"height\":493,\"caption\":\"Peltier-cooled incubator IPP750ecoplus\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp750ecoplus\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP750ecoplus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#website\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/eastwingss-diaa.png\",\"contentUrl\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/eastwings3\",\"http:\\\/\\\/www.linkedin.com\\\/in\\\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp750ecoplus\/","og_locale":"nl_NL","og_type":"article","og_title":"Peltier-cooled incubator IPP750ecoplus","og_description":"Temperature    Setting temperature range 0 to +70 \u00b0C   Working temperature range with light: +10 to +40 \u00b0C   Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C   Setting accuracy temperature 0.1 \u00b0C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days   Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0%   Function SetpointWAIT the process time does not start until the set temperature is reached   Calibration three freely selectable temperature values   adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime    Ventilation    Convection forced ventilation by Peltier fan    Communication    Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display   AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system for fault analysis   Alarm visual and acoustic    Heating concept    Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row   Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle)    Standard equipment    Internals 2 stainless steel grid(s), electropolished   Works calibration certificate for +10\u00b0C and +37\u00b0C   Door inner glass doors   Door fully insulated stainless steel doors with 2-point locking (compression door lock)    Stainless steel interior    Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 1200 x 600\u00a0mm (d less 32 mm for fan - Peltier)   Volume 749\u00a0l   Max. number of internals 14   Max. loading of chamber 200\u00a0kg   Max. loading per internal 30 kg    Textured stainless steel casing    Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1720 x 755\u00a0mm (d +56mm door handle &amp; +111mm Peltier element)   Installation on lockable castors   Housing rear zinc-plated steel    Electrical data    Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W   Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W    Ambient conditions    Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.   Ambient temperature 16 \u00baC to 40 \u00baC   Humidity rh max. 70 %, non-condensing   Altitude of installation max. 2,000 m above sea level   Overvoltage category II   Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp750ecoplus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T12:47:26+00:00","og_image":[{"width":480,"height":493,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/","name":"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","datePublished":"2021-11-16T12:41:30+00:00","dateModified":"2021-11-16T12:47:26+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","width":480,"height":493,"caption":"Peltier-cooled incubator IPP750ecoplus"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP750ecoplus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product\/6962","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media\/6963"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media?parent=6962"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_brand?post=6962"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_cat?post=6962"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_tag?post=6962"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}