{"id":6954,"date":"2021-11-16T12:24:52","date_gmt":"2021-11-16T12:24:52","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6954"},"modified":"2021-11-16T12:27:07","modified_gmt":"2021-11-16T12:27:07","slug":"peltier-cooled-incubator-ipp260ecoplus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp260ecoplus\/","title":{"rendered":"Peltier-gekoelde broedstoof IPP260ecoplus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temperatuur<\/h4>\n\n\n\n\n\n\n\n
Temperatuurbereik instellen:<\/th>\n0 tot +70 \u00b0C<\/td>\n<\/tr>\n
Werktemperatuurbereik:<\/th>\nmet licht: +10 tot +40 \u00b0C<\/td>\n<\/tr>\n
Werktemperatuurbereik:<\/th>\nzonder licht: van 0 (minstens 20 onder de omgevingstemperatuur) tot +70\u00b0C<\/td>\n<\/tr>\n
Nauwkeurigheidstemperatuur instellen:<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Temperatuursensor<\/th>\n2 Pt100-sensoren DIN Klasse A in 4-draads circuit voor onderlinge bewaking, functies overnemen in geval van storing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Besturingstechnologie<\/h4>\n\n\n\n\n\n\n\n\n\n
ControleCOCKPIT<\/th>\nTwinDISPLAY. Adaptieve multifunctionele digitale PID-microprocessorcontroller met 2 high-definition TFT-kleurendisplays.<\/td>\n<\/tr>\n
Taalinstelling<\/th>\nDuits, Engels, Spaans, Frans, Pools, Tsjechisch, Hongaars<\/td>\n<\/tr>\n
Timer<\/th>\nDigitale achterwaartse teller met doeltijdinstelling, instelbaar van 1 minuut tot 99 dagen<\/td>\n<\/tr>\n
Functie HeatBALANCE<\/th>\nde verdeling van het verwarmingsvermogen van het bovenste en onderste verwarmingscircuit aanpassen van -50 % tot +50 %<\/td>\n<\/tr>\n
Functie SetpointWAIT<\/th>\nde procestijd begint pas als de ingestelde temperatuur is bereikt<\/td>\n<\/tr>\n
Kalibratie<\/th>\ndrie vrij te kiezen temperatuurwaarden<\/td>\n<\/tr>\n
instelbare parameters:<\/th>\ntemperatuur (Celsius of Fahrenheit), programmatijd, tijdzones, zomertijd\/wintertijd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilatie<\/h4>\n\n\n\n
Convectie<\/th>\ngeforceerde ventilatie door Peltier-ventilator<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Communicatie<\/h4>\n\n\n\n\n
Documentatie<\/th>\nprogramma opgeslagen in geval van stroomuitval<\/td>\n<\/tr>\n
Programmeren<\/th>\nAtmoCONTROL-software op USB-stick voor het programmeren, beheren en overdragen van programma's via Ethernet-interface of USB-poort<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Veiligheid<\/h4>\n\n\n\n\n\n\n
Temperatuurregeling<\/th>\nover- en ondertemperatuurbewaking TWW, beschermingsklasse 3.3 of instelbare temperatuurbegrenzer TWB, beschermingsklasse 2, selecteerbaar op display<\/td>\n<\/tr>\n
AutoVEILIGHEID<\/th>\nextra ge\u00efntegreerde over- en ondertemperatuurbeveiliging "ASF", automatisch volgen van de gewenste waarde in een vooraf ingesteld tolerantiebereik, alarm bij over- of ondertemperatuur, verwarmingsfunctie wordt uitgeschakeld bij te hoge temperatuur, koelfunctie bij te lage temperatuur<\/td>\n<\/tr>\n
Autodiagnostisch systeem<\/th>\nvoor foutanalyse<\/td>\n<\/tr>\n
Alarm<\/th>\nvisueel en akoestisch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Verwarmingsconcept<\/h4>\n\n\n\n\n
Peltier<\/th>\nVerdeling van verwarmings- en koelprestaties door individuele regeling van de Peltier-elementen in de bovenste en onderste rij<\/td>\n<\/tr>\n
Peltier<\/th>\nenergiebesparend Peltier verwarmings-\/koelsysteem ge\u00efntegreerd in de achterzijde (warmtepompprincipe)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Standaard uitrusting<\/h4>\n\n\n\n\n\n\n
Deur<\/th>\nvolledig ge\u00efsoleerde RVS deur met 2-punts vergrendeling (drukdeurslot)<\/td>\n<\/tr>\n
binnenwerk<\/th>\n2 roestvrijstalen rooster(s), elektrolytisch gepolijst<\/td>\n<\/tr>\n
Werkkalibratiecertificaat<\/th>\nvoor +10\u00b0C en +37\u00b0C<\/td>\n<\/tr>\n
Deur<\/th>\nglazen binnendeur:<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

RVS interieur<\/h4>\n\n\n\n\n\n\n\n
Dimensies<\/th>\nmet wie(EEN)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 640 x 800 x 500 mm (d minus 32 mm voor ventilator \u2013 Peltier)<\/td>\n<\/tr>\n
Volume<\/th>\n256 l<\/td>\n<\/tr>\n
Maximaal aantal internals<\/th>\n9<\/td>\n<\/tr>\n
Maximaal laden van kamer<\/th>\n200 kg<\/td>\n<\/tr>\n
Maximaal laden per intern<\/th>\n20 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Getextureerde roestvrijstalen behuizing<\/h4>\n\n\n\n\n
Dimensies<\/th>\nmet wie(D)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 824 x 1183 x 655 mm (d +56mm deurkruk & +111mm Peltier element)<\/td>\n<\/tr>\n
huisvesting<\/th>\nachter verzinkt staal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Elektrische data<\/h4>\n\n\n\n\n
Spanning Elektrische belasting:<\/th>\n230 V, 50\/60 Hz
\nca. 600 W<\/td>\n<\/tr>\n
Spanning Elektrische belasting:<\/th>\n115 V, 50\/60 Hz
\nca. 600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Omgevingscondities<\/h4>\n\n\n\n\n\n\n\n\n
Opgericht<\/th>\nDe afstand tussen de muur en de achterkant van het apparaat moet minimaal 15 cm zijn. De afstand tot het plafond mag niet minder zijn dan 20 cm en de afstand vanaf de zijkant tot muren of nabije apparaten mag niet minder zijn dan 5 cm.<\/td>\n<\/tr>\n
Omgevingstemperatuur<\/th>\n16 \u00baC tot 40 \u00baC<\/td>\n<\/tr>\n
Vochtigheid rh<\/th>\nmaximaal 70 %, niet-condenserend<\/td>\n<\/tr>\n
Hoogte van installatie<\/th>\nmaximaal 2000 m boven zeeniveau<\/td>\n<\/tr>\n
Overspanningscategorie<\/th>\nII<\/td>\n<\/tr>\n
Vervuilingsgraad<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6955,"template":"","meta":{"nf_dc_page":""},"product_cat":[91],"product_tag":[],"yoast_head":"\nPeltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp260ecoplus\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP260ecoplus\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 32 mm for fan - Peltier) Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 200\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 655\u00a0mm (d +56mm door handle & +111mm Peltier element) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp260ecoplus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T12:27:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP260ecoplus.png?fit=480%2C419&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"419\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\",\"name\":\"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"datePublished\":\"2021-11-16T12:24:52+00:00\",\"dateModified\":\"2021-11-16T12:27:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP260ecoplus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/twitter.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp260ecoplus\/","og_locale":"nl_NL","og_type":"article","og_title":"Peltier-cooled incubator IPP260ecoplus","og_description":"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 32 mm for fan - Peltier) Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 200\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 655\u00a0mm (d +56mm door handle & +111mm Peltier element) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp260ecoplus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T12:27:07+00:00","og_image":[{"width":480,"height":419,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP260ecoplus.png?fit=480%2C419&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/","name":"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"datePublished":"2021-11-16T12:24:52+00:00","dateModified":"2021-11-16T12:27:07+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP260ecoplus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/twitter.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product\/6954"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media\/6955"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media?parent=6954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_cat?post=6954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_tag?post=6954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}