{"id":6945,"date":"2021-11-16T12:11:20","date_gmt":"2021-11-16T12:11:20","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&#038;p=6945"},"modified":"2021-11-16T12:14:04","modified_gmt":"2021-11-16T12:14:04","slug":"peltier-cooled-incubator-ipp30plus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp30plus\/","title":{"rendered":"Peltier-gekoelde broedstoof IPP30plus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<h4>Temperatuur<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Temperatuurbereik instellen:<\/th>\n<td colspan=\"1\">0 tot +70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Werktemperatuurbereik:<\/th>\n<td colspan=\"1\">zonder licht: van 0 (minstens 20 onder de omgevingstemperatuur) tot +70\u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Nauwkeurigheidstemperatuur instellen:<\/th>\n<td colspan=\"1\">0,1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Temperatuursensor<\/th>\n<td colspan=\"1\">2 Pt100-sensoren DIN Klasse A in 4-draads circuit voor onderlinge bewaking, functies overnemen in geval van storing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Besturingstechnologie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">ControleCOCKPIT<\/th>\n<td colspan=\"1\">TwinDISPLAY. Adaptieve multifunctionele digitale PID-microprocessorcontroller met 2 high-definition TFT-kleurendisplays.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Taalinstelling<\/th>\n<td colspan=\"1\">Duits, Engels, Spaans, Frans, Pools, Tsjechisch, Hongaars<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Timer<\/th>\n<td colspan=\"1\">Digitale achterwaartse teller met doeltijdinstelling, instelbaar van 1 minuut tot 99 dagen<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Functie SetpointWAIT<\/th>\n<td colspan=\"1\">de procestijd begint pas als de ingestelde temperatuur is bereikt<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Kalibratie<\/th>\n<td colspan=\"1\">drie vrij te kiezen temperatuurwaarden<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">instelbare parameters:<\/th>\n<td colspan=\"1\">temperatuur (Celsius of Fahrenheit), programmatijd, tijdzones, zomertijd\/wintertijd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Ventilatie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Convectie<\/th>\n<td colspan=\"1\">geforceerde ventilatie door Peltier-ventilator<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Communicatie<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Documentatie<\/th>\n<td colspan=\"1\">programma opgeslagen in geval van stroomuitval<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Programmeren<\/th>\n<td colspan=\"1\">AtmoCONTROL-software op USB-stick voor het programmeren, beheren en overdragen van programma&#039;s via Ethernet-interface of USB-poort<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Veiligheid<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Temperatuurregeling<\/th>\n<td colspan=\"1\">over- en ondertemperatuurbewaking TWW, beschermingsklasse 3.3 of instelbare temperatuurbegrenzer TWB, beschermingsklasse 2, selecteerbaar op display<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">AutoVEILIGHEID<\/th>\n<td colspan=\"1\">extra ge\u00efntegreerde over- en ondertemperatuurbeveiliging &quot;ASF&quot;, automatisch volgen van de gewenste waarde in een vooraf ingesteld tolerantiebereik, alarm bij over- of ondertemperatuur, verwarmingsfunctie wordt uitgeschakeld bij te hoge temperatuur, koelfunctie bij te lage temperatuur<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Autodiagnostisch systeem<\/th>\n<td colspan=\"1\">voor foutanalyse<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Alarm<\/th>\n<td colspan=\"1\">visueel en akoestisch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Verwarmingsconcept<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Peltier<\/th>\n<td colspan=\"1\">energiebesparend Peltier verwarmings-\/koelsysteem ge\u00efntegreerd in de achterzijde (warmtepompprincipe)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Standaard uitrusting<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Deur<\/th>\n<td colspan=\"1\">volledig ge\u00efsoleerde RVS deur met 2-punts vergrendeling (drukdeurslot)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">binnenwerk<\/th>\n<td colspan=\"1\">1 roestvrijstalen rooster(s), elektrolytisch gepolijst<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Werkkalibratiecertificaat<\/th>\n<td colspan=\"1\">voor +10\u00b0C en +37\u00b0C<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Deur<\/th>\n<td colspan=\"1\">glazen binnendeur:<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>RVS interieur<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Dimensies<\/th>\n<td colspan=\"1\">met wie<sub>(EEN)<\/sub>\u00a0xh<sub>(B)<\/sub>\u00a0xd<sub>(C)<\/sub>: 400 x 320 x 250 mm (d min 10 mm voor ventilator \u2013 Peltier)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Volume<\/th>\n<td colspan=\"1\">32 l<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal aantal internals<\/th>\n<td colspan=\"1\">3<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal laden van kamer<\/th>\n<td colspan=\"1\">60 kg<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Maximaal laden per intern<\/th>\n<td colspan=\"1\">20 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Getextureerde roestvrijstalen behuizing<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Dimensies<\/th>\n<td colspan=\"1\">met wie<sub>(D)<\/sub>\u00a0xh<sub>(E)<\/sub>\u00a0xd<sub>(F)<\/sub>: 585 x 704 x 434 mm (d +56mm deurkruk &amp; +111mm Peltier element)<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">huisvesting<\/th>\n<td colspan=\"1\">achter verzinkt staal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Elektrische data<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Spanning Elektrische belasting:<\/th>\n<td colspan=\"1\">230 V, 50\/60 Hz<br \/>\nca. 140 W<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Spanning Elektrische belasting:<\/th>\n<td colspan=\"1\">115 V, 50\/60 Hz<br \/>\nca. 140 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Omgevingscondities<\/h4>\n<table class=\"table\">\n<tbody>\n<tr>\n<th colspan=\"1\">Opgericht<\/th>\n<td colspan=\"1\">De afstand tussen de muur en de achterkant van het apparaat moet minimaal 15 cm zijn. De afstand tot het plafond mag niet minder zijn dan 20 cm en de afstand vanaf de zijkant tot muren of nabije apparaten mag niet minder zijn dan 5 cm.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Omgevingstemperatuur<\/th>\n<td colspan=\"1\">16 \u00baC tot 40 \u00baC<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Vochtigheid rh<\/th>\n<td colspan=\"1\">maximaal 70 %, niet-condenserend<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Hoogte van installatie<\/th>\n<td colspan=\"1\">maximaal 2000 m boven zeeniveau<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Overspanningscategorie<\/th>\n<td colspan=\"1\">II<\/td>\n<\/tr>\n<tr>\n<th colspan=\"1\">Vervuilingsgraad<\/th>\n<td colspan=\"1\">2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6944,"template":"","meta":{"nf_dc_page":""},"product_brand":[],"product_cat":[91],"product_tag":[],"class_list":{"0":"post-6945","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-peltier-cooled-incubator","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.9 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Peltier-cooled incubator IPP30plus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp30plus\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP30plus\" \/>\n<meta property=\"og:description\" content=\"Temperature    Setting temperature range 0 to +70 \u00b0C   Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C   Setting accuracy temperature 0.1 \u00b0C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days   Function SetpointWAIT the process time does not start until the set temperature is reached   Calibration three freely selectable temperature values   adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime    Ventilation    Convection forced ventilation by Peltier fan    Communication    Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display   AutoSAFETY additionally integrated over- and undertemperature protection &quot;ASF&quot;, automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system for fault analysis   Alarm visual and acoustic    Heating concept    Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle)    Standard equipment    Door fully insulated stainless steel door with 2-point locking (compression door lock)   Internals 1 stainless steel grid(s), electropolished   Works calibration certificate for +10\u00b0C and +37\u00b0C   Door inner glass door    Stainless steel interior    Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 400 x 320 x 250\u00a0mm (d less 10 mm for fan - Peltier)   Volume 32\u00a0l   Max. number of internals 3   Max. loading of chamber 60\u00a0kg   Max. loading per internal 20 kg    Textured stainless steel casing    Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 585 x 704 x 434\u00a0mm (d +56mm door handle &amp; +111mm Peltier element)   Housing rear zinc-plated steel    Electrical data    Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 140\u00a0W   Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 140\u00a0W    Ambient conditions    Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.   Ambient temperature 16 \u00baC to 40 \u00baC   Humidity rh max. 70 %, non-condensing   Altitude of installation max. 2,000 m above sea level   Overvoltage category II   Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp30plus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T12:14:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"321\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/\",\"name\":\"Peltier-cooled incubator IPP30plus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1\",\"datePublished\":\"2021-11-16T12:11:20+00:00\",\"dateModified\":\"2021-11-16T12:14:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1\",\"width\":480,\"height\":321,\"caption\":\"Peltier-cooled incubator IPP30\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/product\\\/peltier-cooled-incubator-ipp30plus\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP30plus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#website\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/eastwingss-diaa.png\",\"contentUrl\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\\\/\\\/eastwings-diagnostics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/eastwings3\",\"http:\\\/\\\/www.linkedin.com\\\/in\\\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP30plus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp30plus\/","og_locale":"nl_NL","og_type":"article","og_title":"Peltier-cooled incubator IPP30plus","og_description":"Temperature    Setting temperature range 0 to +70 \u00b0C   Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C   Setting accuracy temperature 0.1 \u00b0C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days   Function SetpointWAIT the process time does not start until the set temperature is reached   Calibration three freely selectable temperature values   adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime    Ventilation    Convection forced ventilation by Peltier fan    Communication    Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display   AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system for fault analysis   Alarm visual and acoustic    Heating concept    Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle)    Standard equipment    Door fully insulated stainless steel door with 2-point locking (compression door lock)   Internals 1 stainless steel grid(s), electropolished   Works calibration certificate for +10\u00b0C and +37\u00b0C   Door inner glass door    Stainless steel interior    Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 400 x 320 x 250\u00a0mm (d less 10 mm for fan - Peltier)   Volume 32\u00a0l   Max. number of internals 3   Max. loading of chamber 60\u00a0kg   Max. loading per internal 20 kg    Textured stainless steel casing    Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 585 x 704 x 434\u00a0mm (d +56mm door handle &amp; +111mm Peltier element)   Housing rear zinc-plated steel    Electrical data    Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 140\u00a0W   Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 140\u00a0W    Ambient conditions    Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.   Ambient temperature 16 \u00baC to 40 \u00baC   Humidity rh max. 70 %, non-condensing   Altitude of installation max. 2,000 m above sea level   Overvoltage category II   Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/nl\/product\/peltier-cooled-incubator-ipp30plus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T12:14:04+00:00","og_image":[{"width":480,"height":321,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/","name":"Peltier-cooled incubator IPP30plus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1","datePublished":"2021-11-16T12:11:20+00:00","dateModified":"2021-11-16T12:14:04+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP30.png?fit=480%2C321&ssl=1","width":480,"height":321,"caption":"Peltier-cooled incubator IPP30"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp30plus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP30plus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product\/6945","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media\/6944"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media?parent=6945"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_brand?post=6945"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_cat?post=6945"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_tag?post=6945"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}