{"id":6941,"date":"2021-11-16T11:08:54","date_gmt":"2021-11-16T11:08:54","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6941"},"modified":"2021-11-16T11:10:29","modified_gmt":"2021-11-16T11:10:29","slug":"co2-incubator-ico240","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/nl\/product\/co2-incubator-ico240\/","title":{"rendered":"CO2-incubator ICO240"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"
\n

Temperatuur<\/h4>\n\n\n\n\n\n\n\n\n
Werktemperatuurbereik:<\/th>\n5 \u00b0C boven omgevingstemperatuur tot +50 \u00b0C
\nStandaard sterilisatieprogramma: 60 minuten op 180\u00b0C (zonder de sensoren te verwijderen)<\/td>\n<\/tr>\n
Temperatuurbereik instellen:<\/th>\n+18 tot +50 \u00b0C<\/td>\n<\/tr>\n
Nauwkeurigheidstemperatuur instellen:<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Temperatuursensor<\/th>\n2 Pt100-sensoren DIN Klasse A in 4-draads circuit voor onderlinge bewaking, functies overnemen in geval van storing<\/td>\n<\/tr>\n
Temperatuurvariatie in kamer<\/th>\nbij + 37 \u00b0C +\/- 0,3 K<\/td>\n<\/tr>\n
Temperatuurschommelingen met de tijd<\/th>\nbij 37 \u00b0C +\/- 0,1 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Vochtigheid<\/h4>\n\n\n\n\n\n
Vochtigheidsregeling (standaard)<\/th>\nVochtigheidsbeperking dankzij een Peltier-element; wanneer de waterschaal vol en geplaatst is, beperkt het Peltier-element de waarde van de relatieve vochtigheid in het interieur tot 93 % rh +\/- 2,5 %<\/td>\n<\/tr>\n
Nauwkeurigheid vochtigheid instellen<\/th>\n0,5 % rh<\/td>\n<\/tr>\n
Instelbereik actieve vochtigheidsregeling (met optie K7)<\/th>\n40 tot 97 % rechts en rechts-uit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Controle van standaardcomponenten<\/h4>\n\n\n\n\n\n\n\n\n
CO2<\/sub>\u00a0controle<\/th>\nDigitale elektronische CO2<\/sub>\u00a0besturing met dubbelstraals NDIR-systeem, met autodiagnosesysteem en akoestische storingsindicatie, luchtdrukcompensatie<\/td>\n<\/tr>\n
Instelbereik CO2<\/sub><\/th>\n0 tot 20 % CO2<\/sub><\/td>\n<\/tr>\n
Instelnauwkeurigheid CO2<\/sub><\/th>\n0,1%<\/td>\n<\/tr>\n
Variatie in tijd CO2<\/sub><\/th>\n+\/- 0,2 % CO2<\/sub><\/td>\n<\/tr>\n
Instelbereik O2<\/sub><\/th>\n1 tot 20 % Uit2<\/sub><\/td>\n<\/tr>\n
Nauwkeurigheid instellen O2<\/sub><\/th>\n0,1 % Uit2<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Besturingstechnologie<\/h4>\n\n\n\n\n\n\n
ControleCOCKPIT<\/th>\nTwinDISPLAY. Adaptieve multifunctionele digitale PID-microprocessorcontroller met 2 high-definition TFT-kleurendisplays.<\/td>\n<\/tr>\n
Taalinstelling<\/th>\nDuits, Engels, Spaans, Frans, Pools, Tsjechisch, Hongaars<\/td>\n<\/tr>\n
Functie SetpointWAIT<\/th>\nde procestijd begint pas als de ingestelde temperatuur is bereikt<\/td>\n<\/tr>\n
Instelbare parameters<\/th>\ntemperatuur (Celsius of Fahrenheit), CO2<\/sub>, programmatijd, tijdzones, zomertijd\/wintertijd<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Communicatie<\/h4>\n\n\n\n\n\n
Koppel<\/th>\nEthernet-LAN, USB<\/td>\n<\/tr>\n
Documentatie<\/th>\nprogramma opgeslagen in geval van stroomuitval<\/td>\n<\/tr>\n
Programmeren<\/th>\nAtmoCONTROL-software op USB-stick voor het programmeren, beheren en overdragen van programma's via Ethernet-interface of USB-poort<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Veiligheid<\/h4>\n\n\n\n\n\n
AutoVEILIGHEID<\/th>\nextra ge\u00efntegreerde over- en ondertemperatuurbeveiliging "ASF", automatisch volgen van de gewenste waarde in een vooraf ingesteld tolerantiebereik, alarm bij over- of ondertemperatuur, verwarmingsfunctie wordt uitgeschakeld bij te hoge temperatuur, koelfunctie bij te lage temperatuur<\/td>\n<\/tr>\n
Autodiagnostisch systeem<\/th>\nintegrale storingsdiagnose voor temperatuur en CO2<\/sub><\/td>\n<\/tr>\n
Alarm<\/th>\nvisueel en akoestisch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Verwarmingsconcept<\/h4>\n\n\n\n
6 kanten<\/th>\nmultifunctioneel verwarmingssysteem met groot oppervlak aan vier zijden met extra deur- en achterverwarming om condensatie te voorkomen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n
\n

Standaard uitrusting<\/h4>\n\n\n\n\n\n\n\n\n
Standaard accessoires<\/th>\nMembraanfilter (om onzuiverheden en verontreinigende stoffen te verwijderen, passeren alle binnenkomende gassen een membraanfilter voordat ze de kamer bereiken)<\/td>\n<\/tr>\n
Deur<\/th>\nvolledig ge\u00efsoleerde RVS deur met 2-punts vergrendeling (drukdeurslot)<\/td>\n<\/tr>\n
binnenwerk<\/th>\n2 geperforeerde roestvrijstalen plank\/planken<\/td>\n<\/tr>\n
Werkkalibratiecertificaat<\/th>\nincl. fabriekskalibratiecertificaat (meetpunt kamercentrum) bij +37\u00b0C, 5 % CO2<\/sub>\u00a0voor standaard units<\/td>\n<\/tr>\n
binnenwerk<\/th>\n1 roestvrijstalen waterschaal<\/td>\n<\/tr>\n
Deur<\/th>\nglazen binnendeur met opening (8 mm \u00d8) om gasmonster te nemen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

RVS interieur<\/h4>\n\n\n\n\n\n\n\n\n
Dimensies<\/th>\nmet wie(EEN)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 600 x 810 x 500 mm (d minus 35 mm voor ventilator)<\/td>\n<\/tr>\n
Interieur<\/th>\nmateriaal 1.4301 (ASTM 304), corrosiebestendig<\/td>\n<\/tr>\n
Volume<\/th>\n241 l<\/td>\n<\/tr>\n
Maximaal aantal internals<\/th>\n12<\/td>\n<\/tr>\n
Maximaal laden van kamer<\/th>\n140 kg<\/td>\n<\/tr>\n
Maximaal laden per intern<\/th>\n15 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Getextureerde roestvrijstalen behuizing<\/h4>\n\n\n\n\n
Dimensies<\/th>\nmet wie(D)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 759 x 1180 x 691 mm (d +56 mm deurkruk)<\/td>\n<\/tr>\n
huisvesting<\/th>\nachter verzinkt staal<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Elektrische data<\/h4>\n\n\n\n\n
Spanning Elektrische belasting:<\/th>\n230 V, 50\/60 Hz
\nca. 1650 W<\/td>\n<\/tr>\n
Spanning Elektrische belasting:<\/th>\n115 V, 50\/60 Hz
\nca. 1650 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Omgevingscondities<\/h4>\n\n\n\n\n\n\n\n\n
Opgericht<\/th>\nDe afstand tussen de muur en de achterkant van het apparaat moet minimaal 15 cm zijn. De afstand tot het plafond mag niet minder zijn dan 20 cm en de afstand vanaf de zijkant tot muren of nabije apparaten mag niet minder zijn dan 5 cm.<\/td>\n<\/tr>\n
Omgevingstemperatuur<\/th>\n10 \u00b0C tot 35 \u00b0C<\/td>\n<\/tr>\n
Vochtigheid rh<\/th>\nmaximaal 70 %, niet-condenserend<\/td>\n<\/tr>\n
Hoogte van installatie<\/th>\nmaximaal 2000 m boven zeeniveau<\/td>\n<\/tr>\n
Overspanningscategorie<\/th>\nII<\/td>\n<\/tr>\n
Vervuilingsgraad<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Verpakkings-\/verzendgegevens<\/h4>\n\n\n\n\n\n\n\n\n\n
Transport informatie<\/th>\nDe apparaten moeten rechtop vervoerd worden<\/td>\n<\/tr>\n
Douanetariefnummer<\/th>\n8419 8998<\/td>\n<\/tr>\n
Land van herkomst<\/th>\nBondsrepubliek Duitsland<\/td>\n<\/tr>\n
WEEE-reg.-nr.<\/th>\nDE 66812464<\/td>\n<\/tr>\n
Afmetingen ca. incl. karton<\/th>\nbxhxd: 840 x 1360 x 900 mm<\/td>\n<\/tr>\n
Netto gewicht<\/th>\nca. 110 kg<\/td>\n<\/tr>\n
Bruto gewicht karton<\/th>\nca. 145 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"featured_media":6942,"template":"","meta":{"nf_dc_page":""},"product_cat":[90],"product_tag":[],"yoast_head":"\nCO2 incubator ICO240 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CO2 incubator ICO240\" \/>\n<meta property=\"og:description\" content=\"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/nl\/product\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T11:10:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"424\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"name\":\"CO2 incubator ICO240 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"datePublished\":\"2021-11-16T11:08:54+00:00\",\"dateModified\":\"2021-11-16T11:10:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"width\":480,\"height\":424,\"caption\":\"CO2 incubator ICO240\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"CO2 incubator ICO240\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/twitter.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/nl\/product\/co2-incubator-ico240\/","og_locale":"nl_NL","og_type":"article","og_title":"CO2 incubator ICO240","og_description":"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg","og_url":"https:\/\/eastwings-diagnostics.com\/nl\/product\/co2-incubator-ico240\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T11:10:29+00:00","og_image":[{"width":480,"height":424,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","url":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","name":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","datePublished":"2021-11-16T11:08:54+00:00","dateModified":"2021-11-16T11:10:29+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","width":480,"height":424,"caption":"CO2 incubator ICO240"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"CO2 incubator ICO240"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/twitter.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product\/6941"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media\/6942"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/media?parent=6941"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_cat?post=6941"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/nl\/wp-json\/wp\/v2\/product_tag?post=6941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}