<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Eastwings Diagnostics Ltd</provider_name><provider_url>https://eastwings-diagnostics.com/nl</provider_url><title>CO2 Incubator ICO50</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="cpN4f4iXwS"&gt;&lt;a href="https://eastwings-diagnostics.com/nl/product/co2-incubator-ico50/"&gt;CO2-incubator ICO50&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://eastwings-diagnostics.com/nl/product/co2-incubator-ico50/embed/#?secret=cpN4f4iXwS" width="600" height="338" title="&#x201C;CO2 Incubator ICO50&#x201D; &#x2014; Eastwings Diagnostics Ltd" data-secret="cpN4f4iXwS" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script type="text/javascript"&gt;
/* &lt;![CDATA[ */
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://eastwings-diagnostics.com/wp-includes/js/wp-embed.min.js
/* ]]&gt; */
&lt;/script&gt;</html><thumbnail_url>https://i0.wp.com/eastwings-diagnostics.com/wp-content/uploads/2021/11/CO2-incubator-ICO50.png?fit=480%2C352&amp;ssl=1</thumbnail_url><thumbnail_width>480</thumbnail_width><thumbnail_height>352</thumbnail_height><description>Temperature    Working-temperature range 5 &#xB0;C above ambient temperature up to +50 &#xB0;C Standard sterilisation programme: 60 minutes at 180&#xB0;C (without removing the sensors)   Setting temperature range +18 to +50 &#xB0;C   Setting accuracy temperature 0.1 &#xB0;C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error   Temperature variation in chamber at + 37 &#xB0;C +/- 0.3 K   Temperature fluctuations with time at 37 &#xB0;C +/- 0.1 K    Humidity    Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93&#xA0;%&#xA0;rh +/- 2.5&#xA0;%   Setting accuracy humidity 0.5&#xA0;% rh   Setting range active humidity control (with option K7) 40 to 97&#xA0;%&#xA0;rh and rh-Off    Control of standard components    CO2&#xA0;control Digital electronic CO2&#xA0;control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation   Adjustment range CO2 0 to 20&#xA0;% CO2   Setting accuracy CO2 0,1%   Variation in time CO2 +/- 0.2&#xA0;% CO2   Adjustment range O2 1 to 20&#xA0;% O2   Setting accuracy O2 0.1&#xA0;% O2    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Function SetpointWAIT the process time does not start until the set temperature is reached   Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime/wintertime    Communication    Interface Ethernet LAN, USB   Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system integral fault diagnostics for temperature and CO2   Alarm visual and acoustic    Heating concept    6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation</description></oembed>
