{"id":6932,"date":"2021-11-16T11:01:01","date_gmt":"2021-11-16T11:01:01","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6932"},"modified":"2021-11-16T11:01:02","modified_gmt":"2021-11-16T11:01:02","slug":"co2-incubator-ico50","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/ko\/product\/co2-incubator-ico50\/","title":{"rendered":"CO2 \uc778\ud050\ubca0\uc774\ud130 ICO50"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

\uc628\ub3c4<\/h4>\n\n\n\n\n\n\n\n\n
\uc791\ub3d9 \uc628\ub3c4 \ubc94\uc704<\/th>\n\uc8fc\ubcc0 \uc628\ub3c4\ubcf4\ub2e4 5\u00b0C \ub192\uac8c \ucd5c\ub300 +50\u00b0C
\n\ud45c\uc900 \uc0b4\uade0 \ud504\ub85c\uadf8\ub7a8: 180\u00b0C\uc5d0\uc11c 60\ubd84(\uc13c\uc11c \uc81c\uac70 \uc5c6\uc774)<\/td>\n<\/tr>\n
\uc124\uc815 \uc628\ub3c4 \ubc94\uc704<\/th>\n+18 ~ +50 \u00b0C<\/td>\n<\/tr>\n
\uc815\ud655\ub3c4 \uc628\ub3c4 \uc124\uc815<\/th>\n0.1 \u00b0C<\/td>\n<\/tr>\n
\uc628\ub3c4 \uc13c\uc11c<\/th>\n2\uac1c\uc758 Pt100 \uc13c\uc11c DIN \ud074\ub798\uc2a4 A, \uc0c1\ud638 \ubaa8\ub2c8\ud130\ub9c1\uc744 \uc704\ud55c 4\uc120\uc2dd \ud68c\ub85c, \uc624\ub958 \ubc1c\uc0dd \uc2dc \uae30\ub2a5 \uc778\uacc4<\/td>\n<\/tr>\n
\ucc54\ubc84\uc758 \uc628\ub3c4 \ubcc0\ud654<\/th>\n+ 37 \u00b0C\uc5d0\uc11c +\/- 0.3K<\/td>\n<\/tr>\n
\uc2dc\uac04\uc5d0 \ub530\ub978 \uc628\ub3c4 \ubcc0\ub3d9<\/th>\n37\u00b0C\uc5d0\uc11c +\/- 0.1K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\uc2b5\uae30<\/h4>\n\n\n\n\n\n
\uc2b5\ub3c4 \uc870\uc808(\ud45c\uc900)<\/th>\nPeltier \uc694\uc18c\ub85c \uc778\ud55c \uc2b5\ub3c4 \uc81c\ud55c; \ubb3c\uadf8\ub987\uc774 \uac00\ub4dd \ucc28\uc11c \uc0bd\uc785\ub418\uba74 \ud3a0\ud2f0\uc5d0 \uc694\uc18c\ub294 \ub0b4\ubd80\uc758 \uc0c1\ub300 \uc2b5\ub3c4 \uac12\uc744 93 % rh +\/- 2.5 %\ub85c \uc81c\ud55c\ud569\ub2c8\ub2e4.<\/td>\n<\/tr>\n
\uc815\ud655\ub3c4 \uc2b5\ub3c4 \uc124\uc815<\/th>\n0.5 % RH<\/td>\n<\/tr>\n
\uc124\uc815 \ubc94\uc704 \ud65c\uc131 \uc2b5\ub3c4 \uc81c\uc5b4(\uc635\uc158 K7 \ud3ec\ud568)<\/th>\n40 ~ 97 % rh \ubc0f rh-Off<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\ud45c\uc900 \uad6c\uc131 \uc694\uc18c\uc758 \uc81c\uc5b4<\/h4>\n\n\n\n\n\n\n\n\n
CO2<\/sub>\u00a0\uc81c\uc5b4<\/th>\n\ub514\uc9c0\ud138 \uc804\uc790 CO2<\/sub>\u00a0\uc774\uc911 \ube54 NDIR \uc2dc\uc2a4\ud15c\uc73c\ub85c \uc81c\uc5b4, \uc790\ub3d9 \uc9c4\ub2e8 \uc2dc\uc2a4\ud15c \ubc0f \uc74c\ud5a5 \uc624\ub958 \ud45c\uc2dc, \uae30\uc555 \ubcf4\uc0c1 \ud3ec\ud568<\/td>\n<\/tr>\n
\uc870\uc815 \ubc94\uc704 CO2<\/sub><\/th>\n0 ~ 20 % CO2<\/sub><\/td>\n<\/tr>\n
\uc124\uc815 \uc815\ud655\ub3c4 CO2<\/sub><\/th>\n0,1%<\/td>\n<\/tr>\n
\uc2dc\uac04\uc758 \ubcc0\ud654 CO2<\/sub><\/th>\n+\/- 0.2 % CO2<\/sub><\/td>\n<\/tr>\n
\uc870\uc815 \ubc94\uc704 O2<\/sub><\/th>\n1 ~ 20 % O2<\/sub><\/td>\n<\/tr>\n
\uc124\uc815 \uc815\ud655\ub3c4 O2<\/sub><\/th>\n0.1 % \uc6242<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\uc81c\uc5b4 \uae30\uc220<\/h4>\n\n\n\n\n\n\n
\ucee8\ud2b8\ub864\ucf55\ud54f<\/th>\n\ud2b8\uc708\ub514\uc2a4\ud50c\ub808\uc774. 2\uac1c\uc758 \uace0\ud654\uc9c8 TFT \uceec\ub7ec \ub514\uc2a4\ud50c\ub808\uc774\uac00 \uc788\ub294 \uc801\uc751\ud615 \ub2e4\uae30\ub2a5 \ub514\uc9c0\ud138 PID \ub9c8\uc774\ud06c\ub85c\ud504\ub85c\uc138\uc11c \ucee8\ud2b8\ub864\ub7ec.<\/td>\n<\/tr>\n
\uc5b8\uc5b4 \uc124\uc815<\/th>\n\ub3c5\uc77c\uc5b4, \uc601\uc5b4, \uc2a4\ud398\uc778\uc5b4, \ud504\ub791\uc2a4\uc5b4, \ud3f4\ub780\ub4dc\uc5b4, \uccb4\ucf54\uc5b4, \ud5dd\uac00\ub9ac\uc5b4<\/td>\n<\/tr>\n
\uae30\ub2a5 \uc124\uc815\uac12WAIT<\/th>\n\uc124\uc815 \uc628\ub3c4\uc5d0 \ub3c4\ub2ec\ud560 \ub54c\uae4c\uc9c0 \ud504\ub85c\uc138\uc2a4 \uc2dc\uac04\uc774 \uc2dc\uc791\ub418\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4.<\/td>\n<\/tr>\n
\uc870\uc815 \uac00\ub2a5\ud55c \ub9e4\uac1c\ubcc0\uc218<\/th>\n\uc628\ub3c4(\uc12d\uc528 \ub610\ub294 \ud654\uc528), CO2<\/sub>, \ud504\ub85c\uadf8\ub7a8 \uc2dc\uac04, \uc2dc\uac04\ub300, \ud558\uc808\uae30\/\ub3d9\uc808\uae30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\uc758\uc0ac \uc18c\ud1b5<\/h4>\n\n\n\n\n\n
\uc0c1\ud638 \uc791\uc6a9<\/th>\n\uc774\ub354\ub137 LAN, USB<\/td>\n<\/tr>\n
\uc120\uc801 \uc11c\ub958 \ube44\uce58<\/th>\n\uc815\uc804 \uc2dc \uc800\uc7a5\ub41c \ud504\ub85c\uadf8\ub7a8<\/td>\n<\/tr>\n
\ud504\ub85c\uadf8\ub7a8 \uc791\uc131<\/th>\n\uc774\ub354\ub137 \uc778\ud130\ud398\uc774\uc2a4 \ub610\ub294 USB \ud3ec\ud2b8\ub97c \ud1b5\ud574 \ud504\ub85c\uadf8\ub7a8\uc744 \ud504\ub85c\uadf8\ub798\ubc0d, \uad00\ub9ac \ubc0f \uc804\uc1a1\ud558\uae30 \uc704\ud55c USB \uc2a4\ud2f1\uc758 AtmoCONTROL \uc18c\ud504\ud2b8\uc6e8\uc5b4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\uc548\uc804<\/h4>\n\n\n\n\n\n
\uc790\ub3d9\uc548\uc804<\/th>\n\ucd94\uac00\ub85c \ud1b5\ud569\ub41c \uacfc\uc628 \ubc0f \uc800\uc628 \ubcf4\ud638 "ASF", \ubbf8\ub9ac \uc124\uc815\ub41c \ud5c8\uc6a9 \uc624\ucc28 \ubc94\uc704\uc5d0\uc11c \uc124\uc815\uac12 \uc790\ub3d9 \ucd94\uc801, \uacfc\uc5f4 \ub610\ub294 \uc800\uc628\uc758 \uacbd\uc6b0 \uacbd\ubcf4, \uacfc\uc5f4\uc758 \uacbd\uc6b0 \uac00\uc5f4 \uae30\ub2a5\uc774 \uaebc\uc9c0\uace0 \uc628\ub3c4\uac00 \ub0ae\uc740 \uacbd\uc6b0 \ub0c9\uac01 \uae30\ub2a5<\/td>\n<\/tr>\n
\uc790\uac00\uc9c4\ub2e8 \uc2dc\uc2a4\ud15c<\/th>\n\uc628\ub3c4 \ubc0f CO\uc5d0 \ub300\ud55c \ud1b5\ud569 \uc624\ub958 \uc9c4\ub2e82<\/sub><\/td>\n<\/tr>\n
\uacbd\ubcf4<\/th>\n\uc2dc\uac01 \ubc0f \uc74c\ud5a5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\ub09c\ubc29 \uac1c\ub150<\/h4>\n\n\n\n
6\uba74<\/th>\n\uacb0\ub85c\ub97c \ubc29\uc9c0\ud558\uae30 \uc704\ud574 \ucd94\uac00 \ub3c4\uc5b4 \ubc0f \ud6c4\uba74 \ub09c\ubc29\uc774 \uc788\ub294 4\uba74\uc758 \ub113\uc740 \uba74\uc801 \ub2e4\uae30\ub2a5 \ub09c\ubc29 \uc2dc\uc2a4\ud15c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6933,"template":"","meta":{"nf_dc_page":""},"product_cat":[90],"product_tag":[],"yoast_head":"\nCO2 Incubator ICO50 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/ko\/product\/co2-incubator-ico50\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CO2 Incubator ICO50\" \/>\n<meta property=\"og:description\" content=\"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/ko\/product\/co2-incubator-ico50\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T11:01:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"352\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/\",\"name\":\"CO2 Incubator ICO50 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1\",\"datePublished\":\"2021-11-16T11:01:01+00:00\",\"dateModified\":\"2021-11-16T11:01:02+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1\",\"width\":480,\"height\":352,\"caption\":\"CO2 incubator ICO50\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"CO2 Incubator ICO50\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/twitter.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CO2 Incubator ICO50 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/ko\/product\/co2-incubator-ico50\/","og_locale":"ko_KR","og_type":"article","og_title":"CO2 Incubator ICO50","og_description":"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation","og_url":"https:\/\/eastwings-diagnostics.com\/ko\/product\/co2-incubator-ico50\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T11:01:02+00:00","og_image":[{"width":480,"height":352,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/","url":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/","name":"CO2 Incubator ICO50 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1","datePublished":"2021-11-16T11:01:01+00:00","dateModified":"2021-11-16T11:01:02+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO50.png?fit=480%2C352&ssl=1","width":480,"height":352,"caption":"CO2 incubator ICO50"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico50\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"CO2 Incubator ICO50"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/twitter.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/product\/6932"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/media\/6933"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/media?parent=6932"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/product_cat?post=6932"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/ko\/wp-json\/wp\/v2\/product_tag?post=6932"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}