<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Eastwings &#xC9C4;&#xB2E8; &#xD68C;&#xC0AC;</provider_name><provider_url>https://eastwings-diagnostics.com/ko</provider_url><title>CO2 incubator ICO240</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="FXnl5zoUxf"&gt;&lt;a href="https://eastwings-diagnostics.com/ko/product/co2-incubator-ico240/"&gt;CO2 &#xC778;&#xD050;&#xBCA0;&#xC774;&#xD130; ICO240&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://eastwings-diagnostics.com/ko/product/co2-incubator-ico240/embed/#?secret=FXnl5zoUxf" width="600" height="338" title="&#x201C;CO2 incubator ICO240&#x201D; &#x2014; Eastwings Diagnostics Ltd" data-secret="FXnl5zoUxf" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script type="text/javascript"&gt;
/* &lt;![CDATA[ */
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://eastwings-diagnostics.com/wp-includes/js/wp-embed.min.js
/* ]]&gt; */
&lt;/script&gt;</html><thumbnail_url>https://i0.wp.com/eastwings-diagnostics.com/wp-content/uploads/2021/11/CO2-incubator-ICO240.png?fit=480%2C424&amp;ssl=1</thumbnail_url><thumbnail_width>480</thumbnail_width><thumbnail_height>424</thumbnail_height><description>Temperature    Working-temperature range 5 &#xB0;C above ambient temperature up to +50 &#xB0;C Standard sterilisation programme: 60 minutes at 180&#xB0;C (without removing the sensors)   Setting temperature range +18 to +50 &#xB0;C   Setting accuracy temperature 0.1 &#xB0;C   Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error   Temperature variation in chamber at + 37 &#xB0;C +/- 0.3 K   Temperature fluctuations with time at 37 &#xB0;C +/- 0.1 K    Humidity    Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93&#xA0;%&#xA0;rh +/- 2.5&#xA0;%   Setting accuracy humidity 0.5&#xA0;% rh   Setting range active humidity control (with option K7) 40 to 97&#xA0;%&#xA0;rh and rh-Off    Control of standard components    CO2&#xA0;control Digital electronic CO2&#xA0;control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation   Adjustment range CO2 0 to 20&#xA0;% CO2   Setting accuracy CO2 0,1%   Variation in time CO2 +/- 0.2&#xA0;% CO2   Adjustment range O2 1 to 20&#xA0;% O2   Setting accuracy O2 0.1&#xA0;% O2    Control technology    ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.   Language setting German, English, Spanish, French, Polish, Czech, Hungarian   Function SetpointWAIT the process time does not start until the set temperature is reached   Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime/wintertime    Communication    Interface Ethernet LAN, USB   Documentation programme stored in case of power failure   Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port    Safety    AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature   Autodiagnostic system integral fault diagnostics for temperature and CO2   Alarm visual and acoustic    Heating concept    6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation      Standard equipment    Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber)   Door fully insulated stainless steel door with 2-point locking (compression door lock)   Internals 2 perforated stainless steel shelf/shelves   Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37&#xB0;C, 5&#xA0;% CO2&#xA0;for standard units   Internals 1 stainless steel water dish   Door inner glass door with opening (8&#xA0;mm &#xD8;) to take gas sample    Stainless steel interior    Dimensions w(A)&#xA0;x h(B)&#xA0;x d(C): 600 x 810 x 500&#xA0;mm (d less 35 mm for fan)   Interior material 1.4301 (ASTM 304), corrosion resistant   Volume 241&#xA0;l   Max. number of internals 12   Max. loading of chamber 140&#xA0;kg   Max. loading per internal 15 kg    Textured stainless steel casing    Dimensions w(D)&#xA0;x h(E)&#xA0;x d(F): 759 x 1180 x 691&#xA0;mm (d +56mm door handle)   Housing rear zinc-plated steel    Electrical data    Voltage Electrical load 230&#xA0;V, 50/60&#xA0;Hz approx. 1650&#xA0;W   Voltage Electrical load 115&#xA0;V, 50/60&#xA0;Hz approx. 1650&#xA0;W    Ambient conditions    Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.   Ambient temperature 10 &#xB0;C to 35 &#xB0;C   Humidity rh max. 70 %, non-condensing   Altitude of installation max. 2,000 m above sea level   Overvoltage category II   Pollution degree 2    Packing/shipping data    Transport information The appliances must be transported upright   Customs tariff number 8419 8998   Country of origin Federal Republic of Germany   WEEE-Reg.-No. DE 66812464   Dimensions approx incl. carton w x h x d: 840 x 1360 x 900&#xA0;mm   Net weight approx. 110&#xA0;kg   Gross weight carton approx. 145&#xA0;kg</description></oembed>
