{"id":7566,"date":"2022-09-21T22:18:17","date_gmt":"2022-09-21T22:18:17","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7566"},"modified":"2022-09-26T13:29:09","modified_gmt":"2022-09-26T13:29:09","slug":"fully-automated-urine-analyzer-aution-max-ax-4060","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/fully-automated-urine-analyzer-aution-max-ax-4060\/","title":{"rendered":"Analyseur d'urine enti\u00e8rement automatis\u00e9 AUTION MAX AX-4060"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Convivial<\/strong><\/p>\n

\u00c9cran tactile couleur pour une bonne convivialit\u00e9 \u00c9cran tactile couleur de 7 pouces \u00e0 haute op\u00e9rabilit\u00e9 affichant les r\u00e9sultats de mesure, les conditions de l'instrument et les instructions d'utilisation.<\/p>\n

Le "Syst\u00e8me de distribution d'\u00e9chantillons" permet de mesurer des \u00e9chantillons de microvolume<\/strong><\/p>\n

Comme l'\u00e9chantillon est aspir\u00e9 \u00e0 travers la buse et livr\u00e9 correctement et quantitativement \u00e0 chaque tampon de la bande, les \u00e9chantillons de microvolume (minimum 1 ml) peuvent \u00eatre mesur\u00e9s facilement. Aucune contamination crois\u00e9e n'est d\u00e9tect\u00e9e sur les portions de r\u00e9actif malgr\u00e9 un volume d'\u00e9chantillon \u00e9lev\u00e9.<\/p>\n

sp\u00e9cification<\/h3>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Objet de mesure<\/th>\nUrine<\/td>\n<\/tr>\n
R\u00e9actif<\/th>\nAUTION Sticks\/ Uriflet S<\/td>\n<\/tr>\n
\u00c9l\u00e9ments de mesure<\/th>\nGLU (Glucose), PRO (Prot\u00e9ine), BIL (Bilirubine), URO (Urobilinog\u00e8ne), PH (pH), BLD (Sang), KET (C\u00e9tones), NIT (Nitrite), LEU (Leucocytes), CRE (Cr\u00e9atinine), ALB (microalbumine), P\/C (rapport prot\u00e9ine\/cr\u00e9atinine), A\/C (rapport albumine\/cr\u00e9atinine), SG (gravit\u00e9 sp\u00e9cifique), turbidit\u00e9 et tonalit\u00e9 de couleur<\/td>\n<\/tr>\n
Plage de mesure<\/th>\nBandelette r\u00e9active : Pour le tableau des classements, voir page 1-12. SG\u00a0: 1,000 \u00e0 1,050 (r\u00e9solution\u00a0: 0,001)
\nNuance de couleur : Pour le diagramme de classification des couleurs, voir page 1-10.
\nTurbidit\u00e9 : Trois niveaux dont \u00ab\u00a0clair\u00a0\u00bb, \u00ab\u00a0turbide\u00a0\u00bb et \u00ab\u00a0turbide dense\u00a0\u00bb<\/td>\n<\/tr>\n
Principe de mesure<\/th>\nBandelette de test : mesure de r\u00e9flectance \u00e0 double longueur d'onde (longueur d'onde unique pour BLD) SG : r\u00e9fractom\u00e9trie de r\u00e9flexion Ton de couleur : mesure de la transmission de la lumi\u00e8re Turbidit\u00e9 : mesure de la diffusion de la lumi\u00e8re<\/td>\n<\/tr>\n
Longueur d'onde de mesure<\/th>\n5 longueurs d'onde LED (450, 525, 562, 635 et 760 nm)<\/td>\n<\/tr>\n
Temps de r\u00e9action de la bandelette de test<\/th>\nEnviron 60 secondes<\/td>\n<\/tr>\n
Stockage des bandelettes r\u00e9actives<\/th>\nDeux compartiments de stockage de bandelettes de test, chacun pouvant contenir diff\u00e9rentes bandelettes de test<\/td>\n<\/tr>\n
Capacit\u00e9 de stockage des bandelettes r\u00e9actives<\/th>\nMaximum 200 bandelettes de test x deux compartiments de stockage<\/td>\n<\/tr>\n
Vitesse de traitement<\/th>\nMesure normale : Maximum 225 \u00e9chantillons\/heure
\nMesure de petit volume : Maximum 112 \u00e9chantillons\/heure<\/td>\n<\/tr>\n
Volume d'\u00e9chantillon requis<\/th>\nMesure normale, STAT : minimum 2 mL
\nMesure de petit volume : Minimum 1 mL<\/td>\n<\/tr>\n
Conteneur d'\u00e9chantillon<\/th>\nTubes \u00e9chantillons (longueur : 95 \u2013 110 mm, diam\u00e8tre : 014,0 \u2013 15,8 mm)<\/td>\n<\/tr>\n
Capacit\u00e9 de chargement des \u00e9chantillons<\/th>\nTransport unidirectionnel (par d\u00e9faut)\u00a0: 50\u00a0\u00e9chantillons maximum
\nTransport en boucle : Maximum 100 \u00e9chantillons<\/td>\n<\/tr>\n
Temps de pr\u00e9chauffage<\/th>\nMaximum 4 minutes<\/td>\n<\/tr>\n
Affichage<\/th>\nGrand \u00e9cran couleur \u00e0 cristaux liquides (800 \u00d7 480 points)<\/td>\n<\/tr>\n
Imprimante int\u00e9gr\u00e9e<\/th>\nPapier d'imprimante de 58 mm de largeur (24 chiffres)<\/td>\n<\/tr>\n
Capacit\u00e9 m\u00e9moire<\/th>\nMesure normale, STAT, petit volume : 2500 tests
\nMesure de contr\u00f4le : 200 tests
\nV\u00e9rifier la mesure : 50 tests
\nListe des probl\u00e8mes\u00a0: 100\u00a0tests<\/td>\n<\/tr>\n
Sortie externe<\/th>\n1 port (rempla\u00e7able par le terminal Ethernet en option)<\/td>\n<\/tr>\n
Syst\u00e8me de communication<\/th>\nConformit\u00e9 RS-232C (commutable entre unidirectionnel et bidirectionnel)<\/td>\n<\/tr>\n
Vitesse de transmission<\/th>\nRS-232C\u00a0: s\u00e9lectionnable entre 300, 600, 1\u00a0200, 2\u00a0400, 4\u00a0800, 9\u00a0600 et 19\u00a0200 bps
\nEthernet : 10BASE-T<\/td>\n<\/tr>\n
Environnement de mesure<\/th>\nTemp\u00e9rature : 10 \u2013 30\u00b0C
\nHumidit\u00e9 : 30 \u2013 60% HR (Sans condensation)<\/td>\n<\/tr>\n
Dimensions<\/th>\n530(W) \u00d7 530(D)\u00d7 530(H) mm (y compris l'\u00e9chantillonneur)<\/td>\n<\/tr>\n
Lester<\/th>\nCorps principal : Environ 40 kg
\n\u00c9chantillonneur : Environ 4 kg<\/td>\n<\/tr>\n
Exigences d'alimentation<\/th>\n100 \u2013 240 V AC (fluctuation maximale de la ligne \u00e9lectrique de \u00b110%)
\n50\/60Hz<\/td>\n<\/tr>\n
Entr\u00e9e de puissance<\/th>\nMaximum 150 VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":7603,"template":"","meta":{"nf_dc_page":""},"product_cat":[57],"product_tag":[],"class_list":{"0":"post-7566","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-urinalysis","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"\nFully Automated Urine Analyzer AUTION MAX AX-4060 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/fully-automated-urine-analyzer-aution-max-ax-4060\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fully Automated Urine Analyzer AUTION MAX AX-4060\" \/>\n<meta property=\"og:description\" content=\"User friendly Color Touch Panel for good usability 7 inch color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. "Sample delivery system" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Specification Measurement object Urine Reagent AUTION Sticks\/ Uriflet S Measurement items GLU (Glucose), PRO (Protein), BIL (Bilirubin), URO(Urobilinogen), PH (pH), BLD (Blood), KET (Ketones),NIT (Nitrite), LEU (Leukocytes), CRE (Creatinine), ALB(Microalbumin), P\/C (Ratio of Protein to Creatinine),A\/C (Ratio of Albumin to Creatinine), S.G. (Specific gravity),turbidity and color tone Measurement range Test strip: For rank table, see page 1-12. S.G.: 1.000 to 1.050(Resolution: 0.001) Color tone: For color classification diagram, see page 1-10. Turbidity: Three levels including "clear", "turbid" and "dense turbid" Measurement principle Test strip: Dual-wavelength reflectance measurement (Single wavelength for BLD) S.G.: Reflection refractometry Color tone: Light-transmission measurement Turbidity:Light-scattering measurement Measurement wavelength 5 LED wavelengths (450, 525, 562, 635 and 760 nm) Test strip reaction time Approximately 60 seconds Test strip storage Two test strip storage compartments, each of which can contain different test strips Test strip storage capacity Maximum 200 test strips x two storage compartments Processing speed Normal measurement: Maximum 225 samples\/hour Small volume measurement: Maximum 112 samples\/hour Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: 014.0 - 15.8 mm) Sample loading capacity One-way transportation (default): Maximum 50 samples Loop transportation: Maximum 100 samples Warm-up time Maximum 4 minutes Display Large color liquid crystal display (800 \u00d7 480 dots) Built-in printer 58-mm width printer paper (24 digits) Memory capacity Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests External output 1 port (Replaceable with the optional Ethernet terminal) Communication system RS-232C compliant (Switchable between one-way and two-way) Transmission speed RS-232C: Selectable from 300, 600, 1200, 2400, 4800,9600 and 19200 bps Ethernet: 10BASE-T Measurement environment Temperature: 10 - 30\u00b0C Humidity: 30 - 60% RH (No condensation) Dimensions 530(W) \u00d7 530(D)\u00d7 530(H) mm(including the sampler) Weight Main body: Approximately 40 kg Sampler: Approximately 4 kg Power requirements 100 - 240 V AC (Maximum power line fluctuation of\u00b110%) 50\/60 Hz Power input Maximum 150 VA\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/fully-automated-urine-analyzer-aution-max-ax-4060\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-26T13:29:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003-1024x683.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/\",\"name\":\"Fully Automated Urine Analyzer AUTION MAX AX-4060 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1\",\"datePublished\":\"2022-09-21T22:18:17+00:00\",\"dateModified\":\"2022-09-26T13:29:09+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1\",\"width\":5679,\"height\":3786,\"caption\":\"AUTION MAX AX-4060\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fully Automated Urine Analyzer AUTION MAX AX-4060\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fully Automated Urine Analyzer AUTION MAX AX-4060 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/fully-automated-urine-analyzer-aution-max-ax-4060\/","og_locale":"fr_FR","og_type":"article","og_title":"Fully Automated Urine Analyzer AUTION MAX AX-4060","og_description":"User friendly Color Touch Panel for good usability 7 inch color touchscreen with high operability displays measurement results, instrument conditions and operating instructions. \"Sample delivery system\" enables micro volume samples to be measured As the sample is drawn through the nozzle and delivered correctly and quantitatively to each pad of the strip, the micro volume samples (minimum 1mL) can be measured easily. No cross contaminations are found on the reagent portions despite high sample volume. Specification Measurement object Urine Reagent AUTION Sticks\/ Uriflet S Measurement items GLU (Glucose), PRO (Protein), BIL (Bilirubin), URO(Urobilinogen), PH (pH), BLD (Blood), KET (Ketones),NIT (Nitrite), LEU (Leukocytes), CRE (Creatinine), ALB(Microalbumin), P\/C (Ratio of Protein to Creatinine),A\/C (Ratio of Albumin to Creatinine), S.G. (Specific gravity),turbidity and color tone Measurement range Test strip: For rank table, see page 1-12. S.G.: 1.000 to 1.050(Resolution: 0.001) Color tone: For color classification diagram, see page 1-10. Turbidity: Three levels including \"clear\", \"turbid\" and \"dense turbid\" Measurement principle Test strip: Dual-wavelength reflectance measurement (Single wavelength for BLD) S.G.: Reflection refractometry Color tone: Light-transmission measurement Turbidity:Light-scattering measurement Measurement wavelength 5 LED wavelengths (450, 525, 562, 635 and 760 nm) Test strip reaction time Approximately 60 seconds Test strip storage Two test strip storage compartments, each of which can contain different test strips Test strip storage capacity Maximum 200 test strips x two storage compartments Processing speed Normal measurement: Maximum 225 samples\/hour Small volume measurement: Maximum 112 samples\/hour Required sample volume Normal, STAT measurement: Minimum 2 mL Small volume measurement: Minimum 1 mL Sample container Sample tubes (length: 95 - 110 mm, diameter: 014.0 - 15.8 mm) Sample loading capacity One-way transportation (default): Maximum 50 samples Loop transportation: Maximum 100 samples Warm-up time Maximum 4 minutes Display Large color liquid crystal display (800 \u00d7 480 dots) Built-in printer 58-mm width printer paper (24 digits) Memory capacity Normal, STAT, small volume measurement: 2500 tests Control measurement: 200 tests Check measurement: 50 tests Trouble list: 100 tests External output 1 port (Replaceable with the optional Ethernet terminal) Communication system RS-232C compliant (Switchable between one-way and two-way) Transmission speed RS-232C: Selectable from 300, 600, 1200, 2400, 4800,9600 and 19200 bps Ethernet: 10BASE-T Measurement environment Temperature: 10 - 30\u00b0C Humidity: 30 - 60% RH (No condensation) Dimensions 530(W) \u00d7 530(D)\u00d7 530(H) mm(including the sampler) Weight Main body: Approximately 40 kg Sampler: Approximately 4 kg Power requirements 100 - 240 V AC (Maximum power line fluctuation of\u00b110%) 50\/60 Hz Power input Maximum 150 VA","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/fully-automated-urine-analyzer-aution-max-ax-4060\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2022-09-26T13:29:09+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003-1024x683.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/","url":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/","name":"Fully Automated Urine Analyzer AUTION MAX AX-4060 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1","datePublished":"2022-09-21T22:18:17+00:00","dateModified":"2022-09-26T13:29:09+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2022\/09\/DPP_0003.png?fit=5679%2C3786&ssl=1","width":5679,"height":3786,"caption":"AUTION MAX AX-4060"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/fully-automated-urine-analyzer-aution-max-ax-4060\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Fully Automated Urine Analyzer AUTION MAX AX-4060"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/7566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/7603"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=7566"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=7566"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=7566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}