{"id":7404,"date":"2021-11-28T22:18:04","date_gmt":"2021-11-28T22:18:04","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7404"},"modified":"2021-11-28T22:22:35","modified_gmt":"2021-11-28T22:22:35","slug":"hettinfo-ii","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/hettinfo-ii\/","title":{"rendered":"HettInfo II"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

TRANSPARENCE ET TRA\u00c7ABILIT\u00c9\u00a0<\/strong><\/p>\n

Avec HettInfo II, ind\u00e9pendant du syst\u00e8me, il est d\u00e9sormais possible de documenter les diff\u00e9rentes \u00e9tapes du processus avant et pendant la centrifugation dans les banques de sang.<\/p>\n

L'\u00e9cran tactile guide l'utilisateur de mani\u00e8re intuitive \u00e0 travers toutes les \u00e9tapes de num\u00e9risation n\u00e9cessaires. Pendant tout le processus, le syst\u00e8me enregistre toutes les donn\u00e9es de processus et les rend disponibles pour l'exportation dans un fichier CSV.<\/p>\n

FAITS ET CHIFFRES<\/h4>\n

PORT\u00c9E HETTINFO II<\/strong>
\nFirmware et \u00e9cran tactile de 4,3 "<\/p>\n

UTILISATEURS<\/strong>
\n3,000<\/p>\n

DONN\u00c9ES DE PROCESSUS ENREGISTR\u00c9ES<\/strong>
\nNom de la centrifugeuse, Donn\u00e9es de la centrifugeuse, Date, Heure de d\u00e9but et de fin, Temp\u00e9rature, Rayon, Heure de d\u00e9but, Temps de d\u00e9c\u00e9l\u00e9ration, Temps de fonctionnement total, RPM, RCF, RCF int\u00e9gral, Temps de cycle, Temps de freinage, Vitesse de freinage d\u00e9sactiv\u00e9, R\u00e9sultat
\nMODULE DE SCAN D'ENREGISTREMENT DE DONN\u00c9ES<\/strong>
\nIdentifiant d'utilisateur. ID de poche de sang, num\u00e9ro de programme<\/p>\n

PORTS<\/strong>
\nLAN, USB<\/p>\n

FORMAT DE FICHIER<\/strong>
\nCSV<\/p>\n

MODULE DE BALAYAGE HETTINFO II<\/h4>\n

Le lecteur de codes-barres enregistre de mani\u00e8re fiable toutes les donn\u00e9es, telles que l'ID de la poche de sang, l'ID utilisateur et le num\u00e9ro de programme.
\nLe support ergonomique assure une manipulation facile et une protection de l'utilisateur pendant la centrifugation.
\nComprend\u00a0:<\/strong><\/p>\n

    \n
  • Lecteur de code-barres<\/strong><\/li>\n
  • Support de montage (y compris les serre-c\u00e2bles)<\/strong><\/li>\n<\/ul>\n

     <\/p>","protected":false},"featured_media":7405,"template":"","meta":{"nf_dc_page":""},"product_cat":[114],"product_tag":[],"class_list":{"0":"post-7404","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-floor-standing-centrifuges","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"\nHettInfo II - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/hettinfo-ii\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HettInfo II\" \/>\n<meta property=\"og:description\" content=\"TRANSPARENCY AND TRACEABILITY\u00a0 With HettInfo II, system-independent, documentation of the individual process steps before and during centrifugation in blood banks is now possible. The touch display guides the user intuitively through all necessary scanning steps. During the entire process, the system records all process data and makes them available for export in a CSV file. FACTS & NUMBERS SCOPE HETTINFO II Firmware and 4.3 " Touchdisplay USERS 3,000 PROCESS DATA RECORDED Centrifuge name, Centrifuge data, Date, Start and end time, Temperature, Radius, Starting time, Deceleration time, Total running time, RPM, RCF, Integral RCF, Cycle time, Braking time, Brake off speed, Result DATA LOGGING SCAN MODULE User ID. Blood bag ID, program number PORTS LAN, USB FILE FORMAT CSV HETTINFO II SCAN MODULE The barcode scanner reliably records all data, such as blood bag ID, user ID and program number. The ergonomic holder ensures easy handling and user protection during centrifugation. Includes: Barcode scanner Mounting Bracket (incl. cable clamps)  \" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/hettinfo-ii\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-28T22:22:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"575\" \/>\n\t<meta property=\"og:image:height\" content=\"575\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/\",\"name\":\"HettInfo II - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1\",\"datePublished\":\"2021-11-28T22:18:04+00:00\",\"dateModified\":\"2021-11-28T22:22:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1\",\"width\":575,\"height\":575},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HettInfo II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HettInfo II - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/hettinfo-ii\/","og_locale":"fr_FR","og_type":"article","og_title":"HettInfo II","og_description":"TRANSPARENCY AND TRACEABILITY\u00a0 With HettInfo II, system-independent, documentation of the individual process steps before and during centrifugation in blood banks is now possible. The touch display guides the user intuitively through all necessary scanning steps. During the entire process, the system records all process data and makes them available for export in a CSV file. FACTS & NUMBERS SCOPE HETTINFO II Firmware and 4.3 \" Touchdisplay USERS 3,000 PROCESS DATA RECORDED Centrifuge name, Centrifuge data, Date, Start and end time, Temperature, Radius, Starting time, Deceleration time, Total running time, RPM, RCF, Integral RCF, Cycle time, Braking time, Brake off speed, Result DATA LOGGING SCAN MODULE User ID. Blood bag ID, program number PORTS LAN, USB FILE FORMAT CSV HETTINFO II SCAN MODULE The barcode scanner reliably records all data, such as blood bag ID, user ID and program number. The ergonomic holder ensures easy handling and user protection during centrifugation. Includes: Barcode scanner Mounting Bracket (incl. cable clamps)  ","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/hettinfo-ii\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-28T22:22:35+00:00","og_image":[{"width":575,"height":575,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/","url":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/","name":"HettInfo II - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1","datePublished":"2021-11-28T22:18:04+00:00","dateModified":"2021-11-28T22:22:35+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/ROTO_SILENTA_mit_HettInfo_II-1.png?fit=575%2C575&ssl=1","width":575,"height":575},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/hettinfo-ii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"HettInfo II"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/7404","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/7405"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=7404"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=7404"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=7404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}