{"id":7380,"date":"2021-11-28T21:45:38","date_gmt":"2021-11-28T21:45:38","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7380"},"modified":"2021-11-28T21:51:28","modified_gmt":"2021-11-28T21:51:28","slug":"rotofix-46-46-h","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/rotofix-46-46-h\/","title":{"rendered":"Rotofix 46 | 46 heures"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

UNIT\u00c9 INDUSTRIELLE ROBUSTE<\/strong><\/p>\n

Ce sont des centrifugeuses id\u00e9ales pour les laboratoires de recherche et industriels. Ils sont robustes et peuvent r\u00e9sister \u00e0 un usage intensif, m\u00eame sur le terrain. Les seaux sp\u00e9cialis\u00e9s peuvent contenir des tubes en forme de poire et coniques ASTM pour les tests p\u00e9troliers.<\/p>\n

L'option chauff\u00e9e fournit une temp\u00e9rature de la chambre jusqu'\u00e0 +90 \u00b0C (ROTOFIX 46 H).<\/p>\n

FAITS ET CHIFFRES<\/h4>\n

MAX. CAPACIT\u00c9:<\/strong>
\n4 x 290 ml | 4 x 100 ml<\/p>\n

MAX. FCR\u00a0:<\/strong>
\n3,095 | 984<\/p>\n

MAX. RPM\u00a0:<\/strong>
\n4000 minutes-1<\/sup>\u00a0| 2 000 minutes-1<\/sup><\/p>\n

POIDS:\u00a0<\/strong>
\nenviron.\u00a0<\/strong>60kg<\/p>\n

CHAUFFAGE:<\/strong>
\nOui<\/p>\n

DIMENSIONS (L x P x H)\u00a0:<\/strong>
\n538 x 647 x 345 mm<\/p>\n

ROTOR OSCILLANT, 4 PLACES<\/h4>\n

Angle:<\/strong>\u00a090\u00b0<\/p>\n

Max. FCR\u00a0:<\/strong>\u00a0984<\/p>\n

Max. RPM\u00a0:<\/strong>\u00a02 000 minutes-1<\/sup><\/p>\n

Max. Capacit\u00e9:<\/strong>\u00a04 x 100 ml<\/p>","protected":false},"featured_media":7381,"template":"","meta":{"nf_dc_page":""},"product_cat":[113],"product_tag":[],"class_list":{"0":"post-7380","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-benchtop-centrifuges","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"\nRotofix 46 | 46 H - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/rotofix-46-46-h\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rotofix 46 | 46 H\" \/>\n<meta property=\"og:description\" content=\"ROBUST INDUSTRIAL UNIT These are ideal centrifuges for research and industrial laboratories. They are robust and can withstand intensive usage, even in the field. Specialty buckets are able to hold ASTM pear-shaped and conical tubes for petroleum testing. Heated option provides chamber temperature up to +90 \u00b0C (ROTOFIX 46 H). FACTS & NUMBERS MAX. CAPACITY: 4 x 290 ml | 4 x 100 ml MAX. RCF: 3,095 | 984 MAX. RPM: 4,000 min-1\u00a0| 2,000\u00a0min-1 WEIGHT:\u00a0 approx.\u00a060 kg HEATING: Yes DIMENSIONS (W x D x H): 538 x 647 x 345 mm SWING-OUT ROTOR, 4- PLACES Angle:\u00a090\u00b0 Max. RCF:\u00a0984 Max. RPM:\u00a02,000 min-1 Max. Capacity:\u00a04 x 100 ml\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/rotofix-46-46-h\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-28T21:51:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"575\" \/>\n\t<meta property=\"og:image:height\" content=\"575\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/\",\"name\":\"Rotofix 46 | 46 H - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1\",\"datePublished\":\"2021-11-28T21:45:38+00:00\",\"dateModified\":\"2021-11-28T21:51:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1\",\"width\":575,\"height\":575},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Rotofix 46 | 46 H\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Rotofix 46 | 46 H - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/rotofix-46-46-h\/","og_locale":"fr_FR","og_type":"article","og_title":"Rotofix 46 | 46 H","og_description":"ROBUST INDUSTRIAL UNIT These are ideal centrifuges for research and industrial laboratories. They are robust and can withstand intensive usage, even in the field. Specialty buckets are able to hold ASTM pear-shaped and conical tubes for petroleum testing. Heated option provides chamber temperature up to +90 \u00b0C (ROTOFIX 46 H). FACTS & NUMBERS MAX. CAPACITY: 4 x 290 ml | 4 x 100 ml MAX. RCF: 3,095 | 984 MAX. RPM: 4,000 min-1\u00a0| 2,000\u00a0min-1 WEIGHT:\u00a0 approx.\u00a060 kg HEATING: Yes DIMENSIONS (W x D x H): 538 x 647 x 345 mm SWING-OUT ROTOR, 4- PLACES Angle:\u00a090\u00b0 Max. RCF:\u00a0984 Max. RPM:\u00a02,000 min-1 Max. Capacity:\u00a04 x 100 ml","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/rotofix-46-46-h\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-28T21:51:28+00:00","og_image":[{"width":575,"height":575,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/","url":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/","name":"Rotofix 46 | 46 H - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1","datePublished":"2021-11-28T21:45:38+00:00","dateModified":"2021-11-28T21:51:28+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Rotofix46.png?fit=575%2C575&ssl=1","width":575,"height":575},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/rotofix-46-46-h\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Rotofix 46 | 46 H"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/7380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/7381"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=7380"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=7380"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=7380"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}