{"id":7244,"date":"2021-11-26T19:59:15","date_gmt":"2021-11-26T19:59:15","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7244"},"modified":"2021-11-26T20:00:48","modified_gmt":"2021-11-26T20:00:48","slug":"incubator-in75plus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/incubator-in75plus\/","title":{"rendered":"Incubateur IN75plus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temp\u00e9rature<\/h4>\n\n\n\n\n\n\n
R\u00e9glage de la plage de temp\u00e9rature<\/th>\n+20 \u00e0 +80 \u00b0C<\/td>\n<\/tr>\n
Plage de temp\u00e9rature de travail<\/th>\nau moins 5 au-dessus de la temp\u00e9rature ambiante \u00e0 +80 \u00b0C<\/td>\n<\/tr>\n
R\u00e9glage de la temp\u00e9rature de pr\u00e9cision<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Capteur de temp\u00e9rature<\/th>\n2 capteurs Pt100 DIN classe A en circuit 4 fils pour surveillance mutuelle, prenant en charge les fonctions en cas d'erreur<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Technologie de contr\u00f4le<\/h4>\n\n\n\n\n\n\n\n\n\n\n
Contr\u00f4leCOCKPIT<\/th>\nTwinDISPLAY. Contr\u00f4leur num\u00e9rique adaptatif multifonctionnel \u00e0 microprocesseur PID avec 2 \u00e9crans couleur TFT haute d\u00e9finition.<\/td>\n<\/tr>\n
Param\u00e8tres de langue<\/th>\nallemand, anglais, espagnol, fran\u00e7ais, polonais, tch\u00e8que, hongrois<\/td>\n<\/tr>\n
Minuteur<\/th>\nCompteur num\u00e9rique \u00e0 rebours avec r\u00e9glage de l'heure cible, r\u00e9glable de 1 minute \u00e0 99 jours<\/td>\n<\/tr>\n
Fonction HeatBALANCE<\/th>\nadaptant la r\u00e9partition des performances de chauffage du circuit de chauffage sup\u00e9rieur et inf\u00e9rieur de -50 % \u00e0 +50 %<\/td>\n<\/tr>\n
Fonction ConsigneWAIT<\/th>\nle temps de processus ne commence pas tant que la temp\u00e9rature de consigne n'est pas atteinte<\/td>\n<\/tr>\n
\u00c9talonnage<\/th>\ntrois valeurs de temp\u00e9rature librement s\u00e9lectionnables<\/td>\n<\/tr>\n
param\u00e8tres r\u00e9glables<\/th>\ntemp\u00e9rature (Celsius ou Fahrenheit), position du volet d'air, heure du programme, fuseaux horaires, heure d'\u00e9t\u00e9\/heure d'hiver<\/td>\n<\/tr>\n
St\u00e9rilisation<\/th>\nprogramme de st\u00e9rilisation fixe (4 heures\/160\u00b0C) pour la st\u00e9rilisation de la chambre de travail, pas pour st\u00e9riliser la charge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilation<\/h4>\n\n\n\n\n\n
Convection<\/th>\nconvection naturelle<\/td>\n<\/tr>\n
Air frais<\/th>\nM\u00e9lange d'air frais pr\u00e9chauff\u00e9 par volet d'air r\u00e9glable \u00e9lectroniquement<\/td>\n<\/tr>\n
\u00c9vent<\/th>\nraccord d'\u00e9vent avec clapet de restriction<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

la communication<\/h4>\n\n\n\n\n
Documentation<\/th>\nprogramme m\u00e9moris\u00e9 en cas de coupure de courant<\/td>\n<\/tr>\n
La programmation<\/th>\nLogiciel AtmoCONTROL sur cl\u00e9 USB pour programmer, g\u00e9rer et transf\u00e9rer des programmes via interface Ethernet ou port USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

S\u00e9curit\u00e9<\/h4>\n\n\n\n\n\n\n\n
Contr\u00f4le de la temp\u00e9rature<\/th>\nlimiteur de temp\u00e9rature m\u00e9canique TB, classe de protection 1 selon DIN 12880 pour \u00e9teindre le chauffage env. 20\u00b0C au dessus de la temp\u00e9rature nominale<\/td>\n<\/tr>\n
Contr\u00f4le de la temp\u00e9rature<\/th>\ncontr\u00f4leur de surchauffe TWW, classe de protection 3.1 ou limiteur de temp\u00e9rature r\u00e9glable TWB, classe de protection 2, s\u00e9lectionnable \u00e0 l'\u00e9cran<\/td>\n<\/tr>\n
AUTOS\u00c9CURIT\u00c9<\/th>\nSurveillance de surchauffe et de sous-temp\u00e9rature int\u00e9gr\u00e9e suppl\u00e9mentaire \u00ab ASF \u00bb, suivant automatiquement la valeur de consigne dans une plage de tol\u00e9rance pr\u00e9d\u00e9finie, alarme en cas de surchauffe ou de sous-temp\u00e9rature, le chauffage est arr\u00eat\u00e9 en cas de surchauffe<\/td>\n<\/tr>\n
Syst\u00e8me d'autodiagnostic<\/th>\npour l'analyse des d\u00e9fauts<\/td>\n<\/tr>\n
Alarme<\/th>\nvisuel et acoustique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\u00c9quipement standard<\/h4>\n\n\n\n\n\n\n
Porte<\/th>\nporte en acier inoxydable enti\u00e8rement isol\u00e9e avec verrouillage 2 points (serrure de porte \u00e0 compression)<\/td>\n<\/tr>\n
Internes<\/th>\n2 grille(s) inox, \u00e9lectropoli<\/td>\n<\/tr>\n
Certificat d'\u00e9talonnage d'usine<\/th>\nincl. certificat d'\u00e9talonnage d'usine pour +37\u00b0C<\/td>\n<\/tr>\n
Porte<\/th>\nporte int\u00e9rieure en verre<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Int\u00e9rieur en acier inoxydable<\/h4>\n\n\n\n\n\n\n\n\n
Int\u00e9rieur<\/th>\nint\u00e9rieur facile \u00e0 nettoyer, en acier inoxydable, renforc\u00e9 par des nervures embouties profondes avec chauffage int\u00e9gr\u00e9 et prot\u00e9g\u00e9 de grande surface sur quatre c\u00f4t\u00e9s<\/td>\n<\/tr>\n
Le volume<\/th>\n74 litres<\/td>\n<\/tr>\n
Dimensions<\/th>\nw(UNE)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 400 x 560 x 330 mm<\/td>\n<\/tr>\n
Max. nombre d'internes<\/th>\n6<\/td>\n<\/tr>\n
Max. chargement de la chambre<\/th>\n120kg<\/td>\n<\/tr>\n
Max. chargement par interne<\/th>\n20kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Bo\u00eetier en acier inoxydable textur\u00e9<\/h4>\n\n\n\n\n
Dimensions<\/th>\nw(R\u00c9)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 585 x 944 x 514 mm (d +56mm poign\u00e9e de porte)<\/td>\n<\/tr>\n
Logement<\/th>\narri\u00e8re en acier zingu\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Donn\u00e9es \u00e9lectriques<\/h4>\n\n\n\n\n
Tension Charge \u00e9lectrique<\/th>\n230 V, 50\/60 Hz
\nenviron. 1250 W<\/td>\n<\/tr>\n
Tension Charge \u00e9lectrique<\/th>\n115 V, 50\/60 Hz
\nenviron. 900 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Conditions ambiantes<\/h4>\n\n\n\n\n\n\n\n\n
D'installation<\/th>\nLa distance entre le mur et l'arri\u00e8re de l'appareil doit \u00eatre d'au moins 15 cm. La distance au plafond ne doit pas \u00eatre inf\u00e9rieure \u00e0 20 cm et la distance lat\u00e9rale aux murs ou aux appareils voisins ne doit pas \u00eatre inf\u00e9rieure \u00e0 5 cm.<\/td>\n<\/tr>\n
Altitude d'installation<\/th>\nmax. 2000 m d'altitude<\/td>\n<\/tr>\n
Temp\u00e9rature ambiante<\/th>\n+5 \u00b0C \u00e0 +40 \u00b0C<\/td>\n<\/tr>\n
Humidit\u00e9 rh<\/th>\nmax. 80 %, sans condensation<\/td>\n<\/tr>\n
Cat\u00e9gorie de surtension<\/th>\nII<\/td>\n<\/tr>\n
Degr\u00e9 de pollution<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":7245,"template":"","meta":{"nf_dc_page":""},"product_cat":[110],"product_tag":[],"class_list":{"0":"post-7244","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-compressor-cooled-incubator","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"yoast_head":"\nIncubator IN75plus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/incubator-in75plus\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Incubator IN75plus\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range at least 5 above ambient temperature to +80 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime\/wintertime Sterilisation fixed sterilisation programme (4\u00a0hours\/160\u00b0C) for sterilisation of working chamber, not for sterilising the load Ventilation Convection natural convection Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Temperature control overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass door Stainless steel interior Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 74\u00a0l Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 400 x 560 x 330\u00a0mm Max. number of internals 6 Max. loading of chamber 120\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 585 x 944 x 514\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1250\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 900\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/incubator-in75plus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-26T20:00:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"405\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/\",\"name\":\"Incubator IN75plus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1\",\"datePublished\":\"2021-11-26T19:59:15+00:00\",\"dateModified\":\"2021-11-26T20:00:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1\",\"width\":480,\"height\":405,\"caption\":\"Incubator IN75plus\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Incubator IN75plus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Incubator IN75plus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/incubator-in75plus\/","og_locale":"fr_FR","og_type":"article","og_title":"Incubator IN75plus","og_description":"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range at least 5 above ambient temperature to +80 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime\/wintertime Sterilisation fixed sterilisation programme (4\u00a0hours\/160\u00b0C) for sterilisation of working chamber, not for sterilising the load Ventilation Convection natural convection Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Temperature control overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature monitor \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass door Stainless steel interior Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 74\u00a0l Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 400 x 560 x 330\u00a0mm Max. number of internals 6 Max. loading of chamber 120\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 585 x 944 x 514\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1250\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 900\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/incubator-in75plus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-26T20:00:48+00:00","og_image":[{"width":480,"height":405,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/","url":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/","name":"Incubator IN75plus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1","datePublished":"2021-11-26T19:59:15+00:00","dateModified":"2021-11-26T20:00:48+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN75plus.png?fit=480%2C405&ssl=1","width":480,"height":405,"caption":"Incubator IN75plus"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/ru\/product\/incubator-in75plus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Incubator IN75plus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/7244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/7245"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=7244"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=7244"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=7244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}