{"id":6962,"date":"2021-11-16T12:41:30","date_gmt":"2021-11-16T12:41:30","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6962"},"modified":"2021-11-16T12:47:26","modified_gmt":"2021-11-16T12:47:26","slug":"peltier-cooled-incubator-ipp750ecoplus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/peltier-cooled-incubator-ipp750ecoplus\/","title":{"rendered":"Incubateur \u00e0 refroidissement Peltier IPP750ecoplus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temp\u00e9rature<\/h4>\n\n\n\n\n\n\n\n
R\u00e9glage de la plage de temp\u00e9rature<\/th>\n0 \u00e0 +70 \u00b0C<\/td>\n<\/tr>\n
Plage de temp\u00e9rature de travail<\/th>\navec lumi\u00e8re : +10 \u00e0 +40 \u00b0C<\/td>\n<\/tr>\n
Plage de temp\u00e9rature de travail<\/th>\nsans lumi\u00e8re : de 0 (au moins 20 en dessous de la temp\u00e9rature ambiante) \u00e0 +70\u00b0C<\/td>\n<\/tr>\n
R\u00e9glage de la temp\u00e9rature de pr\u00e9cision<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Capteur de temp\u00e9rature<\/th>\n2 capteurs Pt100 DIN classe A en circuit 4 fils pour surveillance mutuelle, prenant en charge les fonctions en cas d'erreur<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Technologie de contr\u00f4le<\/h4>\n\n\n\n\n\n\n\n\n\n
Contr\u00f4leCOCKPIT<\/th>\nTwinDISPLAY. Contr\u00f4leur num\u00e9rique adaptatif multifonctionnel \u00e0 microprocesseur PID avec 2 \u00e9crans couleur TFT haute d\u00e9finition.<\/td>\n<\/tr>\n
Param\u00e8tres de langue<\/th>\nallemand, anglais, espagnol, fran\u00e7ais, polonais, tch\u00e8que, hongrois<\/td>\n<\/tr>\n
Minuteur<\/th>\nCompteur num\u00e9rique \u00e0 rebours avec r\u00e9glage de l'heure cible, r\u00e9glable de 1 minute \u00e0 99 jours<\/td>\n<\/tr>\n
Fonction HeatBALANCE<\/th>\nadaptant la r\u00e9partition des performances de chauffage du circuit de chauffage sup\u00e9rieur et inf\u00e9rieur de -50 % \u00e0 +50 %<\/td>\n<\/tr>\n
Fonction ConsigneWAIT<\/th>\nle temps de processus ne commence pas tant que la temp\u00e9rature de consigne n'est pas atteinte<\/td>\n<\/tr>\n
\u00c9talonnage<\/th>\ntrois valeurs de temp\u00e9rature librement s\u00e9lectionnables<\/td>\n<\/tr>\n
param\u00e8tres r\u00e9glables<\/th>\ntemp\u00e9rature (Celsius ou Fahrenheit), heure du programme, fuseaux horaires, heure d'\u00e9t\u00e9\/heure d'hiver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilation<\/h4>\n\n\n\n
Convection<\/th>\nventilation forc\u00e9e par ventilateur Peltier<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

la communication<\/h4>\n\n\n\n\n
Documentation<\/th>\nprogramme m\u00e9moris\u00e9 en cas de coupure de courant<\/td>\n<\/tr>\n
La programmation<\/th>\nLogiciel AtmoCONTROL sur cl\u00e9 USB pour programmer, g\u00e9rer et transf\u00e9rer des programmes via interface Ethernet ou port USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

S\u00e9curit\u00e9<\/h4>\n\n\n\n\n\n\n
Contr\u00f4le de la temp\u00e9rature<\/th>\ncontr\u00f4leur de sur et sous-temp\u00e9rature TWW, classe de protection 3.3 ou limiteur de temp\u00e9rature r\u00e9glable TWB, classe de protection 2, s\u00e9lectionnable sur \u00e9cran<\/td>\n<\/tr>\n
AUTOS\u00c9CURIT\u00c9<\/th>\nprotection contre la surchauffe et la sous-temp\u00e9rature int\u00e9gr\u00e9e en plus \u00ab\u00a0ASF\u00a0\u00bb, suivant automatiquement la valeur de consigne dans une plage de tol\u00e9rance pr\u00e9d\u00e9finie, alarme en cas de surchauffe ou de sous-temp\u00e9rature, fonction de chauffage d\u00e9sactiv\u00e9e en cas de surchauffe, fonction de refroidissement en cas de sous-temp\u00e9rature<\/td>\n<\/tr>\n
Syst\u00e8me d'autodiagnostic<\/th>\npour l'analyse des d\u00e9fauts<\/td>\n<\/tr>\n
Alarme<\/th>\nvisuel et acoustique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Concept de chauffage<\/h4>\n\n\n\n\n
Peltier<\/th>\nR\u00e9partition des performances de chauffage et de refroidissement par contr\u00f4le individuel des \u00e9l\u00e9ments Peltier dans la rang\u00e9e sup\u00e9rieure et inf\u00e9rieure<\/td>\n<\/tr>\n
Peltier<\/th>\nSyst\u00e8me de chauffage\/refroidissement Peltier \u00e0 \u00e9conomie d'\u00e9nergie int\u00e9gr\u00e9 \u00e0 l'arri\u00e8re (principe de la pompe \u00e0 chaleur)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\u00c9quipement standard<\/h4>\n\n\n\n\n\n\n
Internes<\/th>\n2 grille(s) inox, \u00e9lectropoli<\/td>\n<\/tr>\n
Certificat d'\u00e9talonnage d'usine<\/th>\npour +10\u00b0C et +37\u00b0C<\/td>\n<\/tr>\n
Porte<\/th>\nportes int\u00e9rieures en verre<\/td>\n<\/tr>\n
Porte<\/th>\nportes en acier inoxydable enti\u00e8rement isol\u00e9es avec verrouillage 2 points (serrure de porte \u00e0 compression)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Int\u00e9rieur en acier inoxydable<\/h4>\n\n\n\n\n\n\n\n
Dimensions<\/th>\nw(UNE)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 1040 x 1200 x 600 mm (d moins 32 mm pour ventilateur \u2013 Peltier)<\/td>\n<\/tr>\n
Le volume<\/th>\n749 litres<\/td>\n<\/tr>\n
Max. nombre d'internes<\/th>\n14<\/td>\n<\/tr>\n
Max. chargement de la chambre<\/th>\n200 kilogrammes<\/td>\n<\/tr>\n
Max. chargement par interne<\/th>\n30kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Bo\u00eetier en acier inoxydable textur\u00e9<\/h4>\n\n\n\n\n\n
Dimensions<\/th>\nw(R\u00c9)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 1224 x 1720 x 755 mm (d +56mm poign\u00e9e de porte & +111mm \u00e9l\u00e9ment Peltier)<\/td>\n<\/tr>\n
Installation<\/th>\nsur roulettes verrouillables<\/td>\n<\/tr>\n
Logement<\/th>\narri\u00e8re en acier zingu\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Donn\u00e9es \u00e9lectriques<\/h4>\n\n\n\n\n
Tension Charge \u00e9lectrique<\/th>\n230 V, 50\/60 Hz
\nenviron. 1300 W<\/td>\n<\/tr>\n
Tension Charge \u00e9lectrique<\/th>\n115 V, 50\/60 Hz
\nenviron. 1300 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Conditions ambiantes<\/h4>\n\n\n\n\n\n\n\n\n
D'installation<\/th>\nLa distance entre le mur et l'arri\u00e8re de l'appareil doit \u00eatre d'au moins 15 cm. La distance au plafond ne doit pas \u00eatre inf\u00e9rieure \u00e0 20 cm et la distance lat\u00e9rale aux murs ou aux appareils voisins ne doit pas \u00eatre inf\u00e9rieure \u00e0 5 cm.<\/td>\n<\/tr>\n
Temp\u00e9rature ambiante<\/th>\n16 \u00baC \u00e0 40 \u00baC<\/td>\n<\/tr>\n
Humidit\u00e9 rh<\/th>\nmax. 70 %, sans condensation<\/td>\n<\/tr>\n
Altitude d'installation<\/th>\nmax. 2000 m d'altitude<\/td>\n<\/tr>\n
Cat\u00e9gorie de surtension<\/th>\nII<\/td>\n<\/tr>\n
Degr\u00e9 de pollution<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6963,"template":"","meta":{"nf_dc_page":""},"product_cat":[91],"product_tag":[],"class_list":{"0":"post-6962","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-peltier-cooled-incubator","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"\nPeltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/peltier-cooled-incubator-ipp750ecoplus\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP750ecoplus\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass doors Door fully insulated stainless steel doors with 2-point locking (compression door lock) Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 1200 x 600\u00a0mm (d less 32 mm for fan - Peltier) Volume 749\u00a0l Max. number of internals 14 Max. loading of chamber 200\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1720 x 755\u00a0mm (d +56mm door handle & +111mm Peltier element) Installation on lockable castors Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/peltier-cooled-incubator-ipp750ecoplus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T12:47:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"493\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/\",\"name\":\"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"datePublished\":\"2021-11-16T12:41:30+00:00\",\"dateModified\":\"2021-11-16T12:47:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1\",\"width\":480,\"height\":493,\"caption\":\"Peltier-cooled incubator IPP750ecoplus\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP750ecoplus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/peltier-cooled-incubator-ipp750ecoplus\/","og_locale":"fr_FR","og_type":"article","og_title":"Peltier-cooled incubator IPP750ecoplus","og_description":"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass doors Door fully insulated stainless steel doors with 2-point locking (compression door lock) Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 1200 x 600\u00a0mm (d less 32 mm for fan - Peltier) Volume 749\u00a0l Max. number of internals 14 Max. loading of chamber 200\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1720 x 755\u00a0mm (d +56mm door handle & +111mm Peltier element) Installation on lockable castors Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/peltier-cooled-incubator-ipp750ecoplus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T12:47:26+00:00","og_image":[{"width":480,"height":493,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/","name":"Peltier-cooled incubator IPP750ecoplus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","datePublished":"2021-11-16T12:41:30+00:00","dateModified":"2021-11-16T12:47:26+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP750ecoplus.png?fit=480%2C493&ssl=1","width":480,"height":493,"caption":"Peltier-cooled incubator IPP750ecoplus"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp750ecoplus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP750ecoplus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/6962","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/6963"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=6962"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=6962"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=6962"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}