{"id":6941,"date":"2021-11-16T11:08:54","date_gmt":"2021-11-16T11:08:54","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6941"},"modified":"2021-11-16T11:10:29","modified_gmt":"2021-11-16T11:10:29","slug":"co2-incubator-ico240","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/co2-incubator-ico240\/","title":{"rendered":"Incubateur \u00e0 CO2 ICO240"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"
\n

Temp\u00e9rature<\/h4>\n\n\n\n\n\n\n\n\n
Plage de temp\u00e9rature de travail<\/th>\n5 \u00b0C au-dessus de la temp\u00e9rature ambiante jusqu'\u00e0 +50 \u00b0C
\nProgramme de st\u00e9rilisation standard : 60 minutes \u00e0 180\u00b0C (sans retirer les capteurs)<\/td>\n<\/tr>\n
R\u00e9glage de la plage de temp\u00e9rature<\/th>\n+18 \u00e0 +50 \u00b0C<\/td>\n<\/tr>\n
R\u00e9glage de la temp\u00e9rature de pr\u00e9cision<\/th>\n0,1 \u00b0C<\/td>\n<\/tr>\n
Capteur de temp\u00e9rature<\/th>\n2 capteurs Pt100 DIN classe A en circuit 4 fils pour surveillance mutuelle, prenant en charge les fonctions en cas d'erreur<\/td>\n<\/tr>\n
Variation de temp\u00e9rature dans la chambre<\/th>\n\u00e0 + 37 \u00b0C +\/- 0,3 K<\/td>\n<\/tr>\n
Fluctuations de temp\u00e9rature avec le temps<\/th>\n\u00e0 37 \u00b0C +\/- 0,1 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Humidit\u00e9<\/h4>\n\n\n\n\n\n
Contr\u00f4le de l'humidit\u00e9 (standard)<\/th>\nLimitation d'humidit\u00e9 gr\u00e2ce \u00e0 un \u00e9l\u00e9ment Peltier; lorsque le plat d'eau est plein et ins\u00e9r\u00e9, l'\u00e9l\u00e9ment Peltier limite la valeur de l'humidit\u00e9 relative \u00e0 l'int\u00e9rieur \u00e0 93 % rh +\/- 2,5 %<\/td>\n<\/tr>\n
R\u00e9glage de la pr\u00e9cision de l'humidit\u00e9<\/th>\n0,5 % rh<\/td>\n<\/tr>\n
Plage de r\u00e9glage contr\u00f4le d'humidit\u00e9 actif (avec option K7)<\/th>\n40 \u00e0 97 % rh et rh-Off<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Contr\u00f4le des composants standards<\/h4>\n\n\n\n\n\n\n\n\n
CO2<\/sub>\u00a0contr\u00f4ler<\/th>\nCO \u00e9lectronique num\u00e9rique2<\/sub>\u00a0contr\u00f4le avec syst\u00e8me NDIR \u00e0 double faisceau, avec syst\u00e8me d'autodiagnostic et indication acoustique de d\u00e9faut, compensation de la pression barom\u00e9trique<\/td>\n<\/tr>\n
Plage de r\u00e9glage CO2<\/sub><\/th>\n0 \u00e0 20 % CO2<\/sub><\/td>\n<\/tr>\n
Pr\u00e9cision de r\u00e9glage CO2<\/sub><\/th>\n0,1%<\/td>\n<\/tr>\n
Variation dans le temps CO2<\/sub><\/th>\n+\/- 0,2 % CO2<\/sub><\/td>\n<\/tr>\n
Plage de r\u00e9glage O2<\/sub><\/th>\n1 \u00e0 20 % O2<\/sub><\/td>\n<\/tr>\n
Pr\u00e9cision de r\u00e9glage O2<\/sub><\/th>\n0,1 % O2<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Technologie de contr\u00f4le<\/h4>\n\n\n\n\n\n\n
Contr\u00f4leCOCKPIT<\/th>\nTwinDISPLAY. Contr\u00f4leur num\u00e9rique adaptatif multifonctionnel \u00e0 microprocesseur PID avec 2 \u00e9crans couleur TFT haute d\u00e9finition.<\/td>\n<\/tr>\n
Param\u00e8tres de langue<\/th>\nallemand, anglais, espagnol, fran\u00e7ais, polonais, tch\u00e8que, hongrois<\/td>\n<\/tr>\n
Fonction ConsigneWAIT<\/th>\nle temps de processus ne commence pas tant que la temp\u00e9rature de consigne n'est pas atteinte<\/td>\n<\/tr>\n
Param\u00e8tres r\u00e9glables<\/th>\ntemp\u00e9rature (Celsius ou Fahrenheit), CO2<\/sub>, heure du programme, fuseaux horaires, heure d'\u00e9t\u00e9\/heure d'hiver<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

la communication<\/h4>\n\n\n\n\n\n
Interface<\/th>\nLAN Ethernet, USB<\/td>\n<\/tr>\n
Documentation<\/th>\nprogramme m\u00e9moris\u00e9 en cas de coupure de courant<\/td>\n<\/tr>\n
La programmation<\/th>\nLogiciel AtmoCONTROL sur cl\u00e9 USB pour programmer, g\u00e9rer et transf\u00e9rer des programmes via interface Ethernet ou port USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

S\u00e9curit\u00e9<\/h4>\n\n\n\n\n\n
AUTOS\u00c9CURIT\u00c9<\/th>\nprotection contre la surchauffe et la sous-temp\u00e9rature int\u00e9gr\u00e9e en plus \u00ab\u00a0ASF\u00a0\u00bb, suivant automatiquement la valeur de consigne dans une plage de tol\u00e9rance pr\u00e9d\u00e9finie, alarme en cas de surchauffe ou de sous-temp\u00e9rature, fonction de chauffage d\u00e9sactiv\u00e9e en cas de surchauffe, fonction de refroidissement en cas de sous-temp\u00e9rature<\/td>\n<\/tr>\n
Syst\u00e8me d'autodiagnostic<\/th>\ndiagnostic int\u00e9gral des d\u00e9fauts pour la temp\u00e9rature et le CO2<\/sub><\/td>\n<\/tr>\n
Alarme<\/th>\nvisuel et acoustique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Concept de chauffage<\/h4>\n\n\n\n
6 c\u00f4t\u00e9s<\/th>\nsyst\u00e8me de chauffage multifonction de grande surface sur quatre c\u00f4t\u00e9s avec chauffage suppl\u00e9mentaire de la porte et du dos pour \u00e9viter la condensation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n
\n

\u00c9quipement standard<\/h4>\n\n\n\n\n\n\n\n\n
Accessoires standards<\/th>\nFiltre \u00e0 membrane (afin d'\u00e9liminer les impuret\u00e9s et les polluants, tous les gaz entrants passent \u00e0 travers un filtre \u00e0 membrane avant d'atteindre la chambre)<\/td>\n<\/tr>\n
Porte<\/th>\nporte en acier inoxydable enti\u00e8rement isol\u00e9e avec verrouillage 2 points (serrure de porte \u00e0 compression)<\/td>\n<\/tr>\n
Internes<\/th>\n2 \u00e9tag\u00e8res perfor\u00e9es en acier inoxydable<\/td>\n<\/tr>\n
Certificat d'\u00e9talonnage des travaux<\/th>\nincl. certificat d'\u00e9talonnage d'usine (point de mesure centre de la chambre) \u00e0 +37\u00b0C, 5 % CO2<\/sub>\u00a0pour les unit\u00e9s standard<\/td>\n<\/tr>\n
Internes<\/th>\n1 plat d'eau en acier inoxydable<\/td>\n<\/tr>\n
Porte<\/th>\nporte int\u00e9rieure vitr\u00e9e avec ouverture (8 mm \u00d8) pour pr\u00e9l\u00e8vement de gaz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Int\u00e9rieur en acier inoxydable<\/h4>\n\n\n\n\n\n\n\n\n
Dimensions<\/th>\nw(UNE)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 600 x 810 x 500 mm (d moins 35 mm pour ventilateur)<\/td>\n<\/tr>\n
Int\u00e9rieur<\/th>\nmat\u00e9riau 1.4301 (ASTM 304), r\u00e9sistant \u00e0 la corrosion<\/td>\n<\/tr>\n
Le volume<\/th>\n241 litres<\/td>\n<\/tr>\n
Max. nombre d'internes<\/th>\n12<\/td>\n<\/tr>\n
Max. chargement de la chambre<\/th>\n140 kilogrammes<\/td>\n<\/tr>\n
Max. chargement par interne<\/th>\n15kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Bo\u00eetier en acier inoxydable textur\u00e9<\/h4>\n\n\n\n\n
Dimensions<\/th>\nw(R\u00c9)<\/sub>\u00a0xh(E)<\/sub>\u00a0xd(F)<\/sub>: 759 x 1180 x 691 mm (d +56mm poign\u00e9e de porte)<\/td>\n<\/tr>\n
Logement<\/th>\narri\u00e8re en acier zingu\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Donn\u00e9es \u00e9lectriques<\/h4>\n\n\n\n\n
Tension Charge \u00e9lectrique<\/th>\n230 V, 50\/60 Hz
\nenviron. 1650 W<\/td>\n<\/tr>\n
Tension Charge \u00e9lectrique<\/th>\n115 V, 50\/60 Hz
\nenviron. 1650 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Conditions ambiantes<\/h4>\n\n\n\n\n\n\n\n\n
D'installation<\/th>\nLa distance entre le mur et l'arri\u00e8re de l'appareil doit \u00eatre d'au moins 15 cm. La distance au plafond ne doit pas \u00eatre inf\u00e9rieure \u00e0 20 cm et la distance lat\u00e9rale aux murs ou aux appareils voisins ne doit pas \u00eatre inf\u00e9rieure \u00e0 5 cm.<\/td>\n<\/tr>\n
Temp\u00e9rature ambiante<\/th>\n10 \u00b0C \u00e0 35 \u00b0C<\/td>\n<\/tr>\n
Humidit\u00e9 rh<\/th>\nmax. 70 %, sans condensation<\/td>\n<\/tr>\n
Altitude d'installation<\/th>\nmax. 2000 m d'altitude<\/td>\n<\/tr>\n
Cat\u00e9gorie de surtension<\/th>\nII<\/td>\n<\/tr>\n
Degr\u00e9 de pollution<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Donn\u00e9es d'emballage\/d'exp\u00e9dition<\/h4>\n\n\n\n\n\n\n\n\n\n
Informations de transport<\/th>\nLes appareils doivent \u00eatre transport\u00e9s debout<\/td>\n<\/tr>\n
Num\u00e9ro de tarif douanier<\/th>\n8419 8998<\/td>\n<\/tr>\n
Pays d'origine<\/th>\nR\u00e9publique F\u00e9d\u00e9rale d'Allemagne<\/td>\n<\/tr>\n
DEEE-Reg.-No.<\/th>\nDE 66812464<\/td>\n<\/tr>\n
Dimensions env. carton<\/th>\nlxhxp : 840 x 1360 x 900 mm<\/td>\n<\/tr>\n
Poids net<\/th>\nenviron. 110kg<\/td>\n<\/tr>\n
Carton de poids brut<\/th>\nenviron. 145 kilogrammes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"featured_media":6942,"template":"","meta":{"nf_dc_page":""},"product_cat":[90],"product_tag":[],"class_list":{"0":"post-6941","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-co2-incubator","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"\nCO2 incubator ICO240 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CO2 incubator ICO240\" \/>\n<meta property=\"og:description\" content=\"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/fr\/produit\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T11:10:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"424\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"name\":\"CO2 incubator ICO240 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"datePublished\":\"2021-11-16T11:08:54+00:00\",\"dateModified\":\"2021-11-16T11:10:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"width\":480,\"height\":424,\"caption\":\"CO2 incubator ICO240\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"CO2 incubator ICO240\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/co2-incubator-ico240\/","og_locale":"fr_FR","og_type":"article","og_title":"CO2 incubator ICO240","og_description":"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg","og_url":"https:\/\/eastwings-diagnostics.com\/fr\/produit\/co2-incubator-ico240\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T11:10:29+00:00","og_image":[{"width":480,"height":424,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","url":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","name":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","datePublished":"2021-11-16T11:08:54+00:00","dateModified":"2021-11-16T11:10:29+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","width":480,"height":424,"caption":"CO2 incubator ICO240"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"CO2 incubator ICO240"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product\/6941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media\/6942"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/media?parent=6941"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_cat?post=6941"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/fr\/wp-json\/wp\/v2\/product_tag?post=6941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}