{"id":7274,"date":"2021-11-27T04:55:54","date_gmt":"2021-11-27T04:55:54","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=7274"},"modified":"2021-11-27T04:57:41","modified_gmt":"2021-11-27T04:57:41","slug":"incubator-in450","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/es\/producto\/incubator-in450\/","title":{"rendered":"Incubadora IN450"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temperatura<\/h4>\n\n\n\n\n\n\n
Ajuste del rango de temperatura<\/th>\n+20 hasta +80 \u00b0 C<\/td>\n<\/tr>\n
Rango de temperatura de trabajo<\/th>\nal menos 5 por encima de la temperatura ambiente hasta +80 \u00b0 C<\/td>\n<\/tr>\n
Ajuste de la temperatura de precisi\u00f3n<\/th>\n0,1 \u00b0 C<\/td>\n<\/tr>\n
Sensor de temperatura<\/th>\n1 sensor Pt100 DIN clase A en circuito de 4 hilos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Tecnolog\u00eda de control<\/h4>\n\n\n\n\n\n\n\n\n
Configuraci\u00f3n de idioma<\/th>\nAlem\u00e1n, ingl\u00e9s, espa\u00f1ol, franc\u00e9s, polaco, checo, h\u00fangaro<\/td>\n<\/tr>\n
ControlCOCKPIT<\/th>\nSingleDISPLAY. Controlador de microprocesador PID digital multifuncional adaptable con pantalla a color TFT de alta definici\u00f3n<\/td>\n<\/tr>\n
Temporizador<\/th>\nContador de retroceso digital con ajuste de tiempo objetivo, ajustable de 1 minuto a 99 d\u00edas<\/td>\n<\/tr>\n
Funci\u00f3n SetpointWAIT<\/th>\nel tiempo de proceso no comienza hasta que se alcanza la temperatura establecida<\/td>\n<\/tr>\n
Calibraci\u00f3n<\/th>\ntres valores de temperatura libremente seleccionables<\/td>\n<\/tr>\n
par\u00e1metros ajustables<\/th>\ntemperatura (Celsius o Fahrenheit), posici\u00f3n de la aleta de aire, tiempo del programa, zonas horarias, horario de verano \/ invierno<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilaci\u00f3n<\/h4>\n\n\n\n\n\n
Convecci\u00f3n<\/th>\nconvecci\u00f3n natural<\/td>\n<\/tr>\n
Aire fresco<\/th>\nMezcla de aire fresco precalentado mediante trampilla de aire regulable electr\u00f3nicamente<\/td>\n<\/tr>\n
Respiradero<\/th>\nconexi\u00f3n de ventilaci\u00f3n con aleta restrictiva<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Comunicaci\u00f3n<\/h4>\n\n\n\n\n
Documentaci\u00f3n<\/th>\nprograma almacenado en caso de corte de energ\u00eda<\/td>\n<\/tr>\n
Programaci\u00f3n<\/th>\nSoftware AtmoCONTROL para leer, gestionar y organizar el registrador de datos a trav\u00e9s de la interfaz Ethernet (se puede descargar la versi\u00f3n de prueba temporal). Memoria USB con software AtmoCONTROL disponible como accesorio (bajo demanda).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Seguridad<\/h4>\n\n\n\n\n
Control de temperatura<\/th>\nmonitor electr\u00f3nico de sobretemperatura regulable y limitador de temperatura mec\u00e1nico TB, clase de protecci\u00f3n 1 seg\u00fan DIN 12880 para desconectar la calefacci\u00f3n aprox. 20 \u00b0 C por encima de la temperatura nominal<\/td>\n<\/tr>\n
Sistema de autodiagn\u00f3stico<\/th>\npara an\u00e1lisis de fallas<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Equipamiento estandar<\/h4>\n\n\n\n\n\n\n
Internos<\/th>\n2 rejillas de acero inoxidable, electropulidas<\/td>\n<\/tr>\n
Certificado de calibraci\u00f3n de obra<\/th>\nincl. funciona certificado de calibraci\u00f3n para + 37 \u00b0 C<\/td>\n<\/tr>\n
Puerta<\/th>\npuertas interiores de cristal<\/td>\n<\/tr>\n
Puerta<\/th>\npuertas de acero inoxidable totalmente aisladas con bloqueo de 2 puntos (bloqueo de puerta de compresi\u00f3n)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Interior de acero inoxidable<\/h4>\n\n\n\n\n\n\n\n\n
Interior<\/th>\ninterior f\u00e1cil de limpiar, de acero inoxidable, reforzado por nervaduras embutidas con calefacci\u00f3n integrada y protegida de gran superficie en los cuatro lados<\/td>\n<\/tr>\n
Volumen<\/th>\n449 litros<\/td>\n<\/tr>\n
Dimensiones<\/th>\nw(A)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 1040 x 720 x 600 mm<\/td>\n<\/tr>\n
Max. n\u00famero de internos<\/th>\n8<\/td>\n<\/tr>\n
Max. carga de la c\u00e1mara<\/th>\n300 kilogramos<\/td>\n<\/tr>\n
Max. cargando por interno<\/th>\n30 kilogramos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Carcasa de acero inoxidable con textura<\/h4>\n\n\n\n\n\n
Dimensiones<\/th>\nw(D)<\/sub>\u00a0xh(MI)<\/sub>\u00a0xd(F)<\/sub>: 1224 x 1247 x 784 mm (manija de puerta d + 56 mm)<\/td>\n<\/tr>\n
Instalaci\u00f3n<\/th>\nsobre ruedas bloqueables<\/td>\n<\/tr>\n
Alojamiento<\/th>\ntrasero de acero cincado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Datos el\u00e9ctricos<\/h4>\n\n\n\n\n
Voltaje Carga el\u00e9ctrica<\/th>\n230 V, 50\/60 Hz
\naprox. 1800 W<\/td>\n<\/tr>\n
Voltaje Carga el\u00e9ctrica<\/th>\n115 V, 50\/60 Hz
\naprox. 1500 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Condiciones ambientales<\/h4>\n\n\n\n\n\n\n\n\n
Configurar<\/th>\nLa distancia entre la pared y la parte trasera del aparato debe ser de al menos 15 cm. El espacio libre desde el techo no debe ser inferior a 20 cm y el espacio libre lateral desde las paredes o los electrodom\u00e9sticos cercanos no debe ser inferior a 5 cm.<\/td>\n<\/tr>\n
Altitud de instalaci\u00f3n<\/th>\nm\u00e1x. 2000 m sobre el nivel del mar<\/td>\n<\/tr>\n
Temperatura ambiente<\/th>\n+5 \u00b0 C hasta +40 \u00b0 C<\/td>\n<\/tr>\n
Humedad rh<\/th>\nm\u00e1x. 80 %, sin condensaci\u00f3n<\/td>\n<\/tr>\n
Categor\u00eda de sobrevoltaje<\/th>\nII<\/td>\n<\/tr>\n
Grado de contaminaci\u00f3n<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":7275,"template":"","meta":{"nf_dc_page":""},"product_cat":[110],"product_tag":[],"yoast_head":"\nIncubator IN450 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/incubator-in450\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Incubator IN450\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range at least 5 above ambient temperature to +80 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 1 Pt100 sensor DIN class A in 4-wire-circuit Control technology Language setting German, English, Spanish, French, Polish, Czech, Hungarian ControlCOCKPIT SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime\/wintertime Ventilation Convection natural convection Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Autodiagnostic system for fault analysis Standard equipment Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass doors Door fully insulated stainless steel doors with 2-point locking (compression door lock) Stainless steel interior Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 449\u00a0l Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 720 x 600\u00a0mm Max. number of internals 8 Max. loading of chamber 300\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1247 x 784\u00a0mm (d +56mm door handle) Installation on lockable castors Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1800\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1500\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/incubator-in450\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-27T04:57:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/\",\"name\":\"Incubator IN450 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1\",\"datePublished\":\"2021-11-27T04:55:54+00:00\",\"dateModified\":\"2021-11-27T04:57:41+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1\",\"width\":480,\"height\":355,\"caption\":\"Incubator IN450\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Incubator IN450\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Incubator IN450 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/es\/producto\/incubator-in450\/","og_locale":"es_ES","og_type":"article","og_title":"Incubator IN450","og_description":"Temperature Setting temperature range +20 to +80 \u00b0C Working temperature range at least 5 above ambient temperature to +80 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 1 Pt100 sensor DIN class A in 4-wire-circuit Control technology Language setting German, English, Spanish, French, Polish, Czech, Hungarian ControlCOCKPIT SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), air flap position, programme time, time zones, summertime\/wintertime Ventilation Convection natural convection Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap Vent vent connection with restrictor flap Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20\u00b0C above nominal temperature Autodiagnostic system for fault analysis Standard equipment Internals 2 stainless steel grid(s), electropolished Works calibration certificate incl. works calibration certificate for +37\u00b0C Door inner glass doors Door fully insulated stainless steel doors with 2-point locking (compression door lock) Stainless steel interior Interior easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides Volume 449\u00a0l Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1040 x 720 x 600\u00a0mm Max. number of internals 8 Max. loading of chamber 300\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1224 x 1247 x 784\u00a0mm (d +56mm door handle) Installation on lockable castors Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1800\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1500\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Altitude of installation max. 2,000 m above sea level Ambient temperature +5 \u00b0C to +40 \u00b0C Humidity rh max. 80 %, non-condensing Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/es\/producto\/incubator-in450\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-27T04:57:41+00:00","og_image":[{"width":480,"height":355,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/","url":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/","name":"Incubator IN450 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1","datePublished":"2021-11-27T04:55:54+00:00","dateModified":"2021-11-27T04:57:41+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Incubator-IN450.png?fit=480%2C355&ssl=1","width":480,"height":355,"caption":"Incubator IN450"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/incubator-in450\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Incubator IN450"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product\/7274"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media\/7275"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media?parent=7274"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_cat?post=7274"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_tag?post=7274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}