{"id":6974,"date":"2021-11-16T13:01:47","date_gmt":"2021-11-16T13:01:47","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6974"},"modified":"2021-11-16T13:19:05","modified_gmt":"2021-11-16T13:19:05","slug":"peltier-cooled-incubator-ipp1400ecoplus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp1400ecoplus\/","title":{"rendered":"Incubadora refrigerada por Peltier IPP1400ecoplus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temperatura<\/h4>\n\n\n\n\n\n\n
Ajuste del rango de temperatura<\/th>\n0 hasta +70 \u00b0 C<\/td>\n<\/tr>\n
Rango de temperatura de trabajo<\/th>\nsin luz: de 0 (al menos 20 por debajo de la temperatura ambiente) a + 70 \u00b0 C<\/td>\n<\/tr>\n
Ajuste de la temperatura de precisi\u00f3n<\/th>\n0,1 \u00b0 C<\/td>\n<\/tr>\n
Sensor de temperatura<\/th>\n2 sensores Pt100 DIN Clase A en circuito de 4 hilos para monitoreo mutuo, asumiendo funciones en caso de error<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Tecnolog\u00eda de control<\/h4>\n\n\n\n\n\n\n\n\n
ControlCOCKPIT<\/th>\nTwinDISPLAY. Controlador de microprocesador PID digital multifuncional adaptativo con 2 pantallas TFT en color de alta definici\u00f3n.<\/td>\n<\/tr>\n
Configuraci\u00f3n de idioma<\/th>\nAlem\u00e1n, ingl\u00e9s, espa\u00f1ol, franc\u00e9s, polaco, checo, h\u00fangaro<\/td>\n<\/tr>\n
Temporizador<\/th>\nContador de retroceso digital con ajuste de tiempo objetivo, ajustable de 1 minuto a 99 d\u00edas<\/td>\n<\/tr>\n
Funci\u00f3n SetpointWAIT<\/th>\nel tiempo de proceso no comienza hasta que se alcanza la temperatura establecida<\/td>\n<\/tr>\n
Calibraci\u00f3n<\/th>\ntres valores de temperatura libremente seleccionables<\/td>\n<\/tr>\n
par\u00e1metros ajustables<\/th>\ntemperatura (Celsius o Fahrenheit), tiempo del programa, zonas horarias, horario de verano \/ invierno<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilaci\u00f3n<\/h4>\n\n\n\n
Convecci\u00f3n<\/th>\nventilaci\u00f3n forzada por ventilador Peltier<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Comunicaci\u00f3n<\/h4>\n\n\n\n\n
Documentaci\u00f3n<\/th>\nprograma almacenado en caso de corte de energ\u00eda<\/td>\n<\/tr>\n
Programaci\u00f3n<\/th>\nSoftware AtmoCONTROL en una memoria USB para programar, administrar y transferir programas a trav\u00e9s de la interfaz Ethernet o el puerto USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Seguridad<\/h4>\n\n\n\n\n
Control de temperatura<\/th>\nmonitor de sobretemperatura electr\u00f3nico ajustable y limitador de temperatura mec\u00e1nico<\/td>\n<\/tr>\n
Sistema de autodiagn\u00f3stico<\/th>\npara an\u00e1lisis de fallas<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Concepto de calefacci\u00f3n<\/h4>\n\n\n\n
Peltier<\/th>\nSistema de calefacci\u00f3n \/ refrigeraci\u00f3n Peltier de ahorro de energ\u00eda integrado en la parte trasera (principio de bomba de calor)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Equipamiento estandar<\/h4>\n\n\n\n\n\n
Certificado de calibraci\u00f3n de obra<\/th>\npara +25 \u00b0 C y +40 \u00b0 C<\/td>\n<\/tr>\n
Internos<\/th>\n4 rejillas de acero inoxidable, electropulidas<\/td>\n<\/tr>\n
Puerta<\/th>\nPuertas de acero inoxidable con sectores de vidrio, lunas de vidrio interiores totalmente calefaccionadas integradas en la puerta de vidrio con visibilidad total con bloqueo de 2 puntos (cerradura de puerta de compresi\u00f3n)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Interior de acero inoxidable<\/h4>\n\n\n\n\n\n\n\n
Dimensiones<\/th>\nw(A)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 1250 x 1450 x 750 mm (d menos 32 mm para ventilador - Peltier)<\/td>\n<\/tr>\n
Volumen<\/th>\n1360 litros<\/td>\n<\/tr>\n
Max. n\u00famero de internos<\/th>\n28<\/td>\n<\/tr>\n
Max. carga de la c\u00e1mara<\/th>\n250 kilogramos<\/td>\n<\/tr>\n
Max. cargando por interno<\/th>\n30 kilogramos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Carcasa de acero inoxidable con textura<\/h4>\n\n\n\n\n\n
Dimensiones<\/th>\nw(D)<\/sub>\u00a0xh(MI)<\/sub>\u00a0xd(F)<\/sub>: 1435 x 1913 x 905 mm (d + manija de puerta de 56 mm y elemento Peltier de + 111 mm)<\/td>\n<\/tr>\n
Instalaci\u00f3n<\/th>\nsobre ruedas bloqueables, regulable en altura<\/td>\n<\/tr>\n
Alojamiento<\/th>\ntrasero de acero cincado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Datos el\u00e9ctricos<\/h4>\n\n\n\n\n
Voltaje Carga el\u00e9ctrica<\/th>\n230 V, 50\/60 Hz
\naprox. 1300 W<\/td>\n<\/tr>\n
Voltaje Carga el\u00e9ctrica<\/th>\n115 V, 50\/60 Hz
\naprox. 1300 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Condiciones ambientales<\/h4>\n\n\n\n\n\n\n\n\n
Configurar<\/th>\nLa distancia entre la pared y la parte trasera del aparato debe ser de al menos 15 cm. El espacio libre desde el techo no debe ser inferior a 20 cm y el espacio libre lateral desde las paredes o los electrodom\u00e9sticos cercanos no debe ser inferior a 5 cm.<\/td>\n<\/tr>\n
Temperatura ambiente<\/th>\n16 \u00baC a 40 \u00baC<\/td>\n<\/tr>\n
Humedad rh<\/th>\nm\u00e1x. 70 %, sin condensaci\u00f3n<\/td>\n<\/tr>\n
Altitud de instalaci\u00f3n<\/th>\nm\u00e1x. 2000 m sobre el nivel del mar<\/td>\n<\/tr>\n
Categor\u00eda de sobrevoltaje<\/th>\nII<\/td>\n<\/tr>\n
Grado de contaminaci\u00f3n<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6975,"template":"","meta":{"nf_dc_page":""},"product_cat":[91],"product_tag":[],"class_list":{"0":"post-6974","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-peltier-cooled-incubator","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"product-type-simple"},"yoast_head":"\nPeltier-cooled incubator IPP1400ecoplus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp1400ecoplus\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP1400ecoplus\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter Autodiagnostic system for fault analysis Heating concept Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Works calibration certificate for +25 \u00b0C and +40 \u00b0C Internals 4 stainless steel grid(s), electropolished Door Stainless steel doors with glass sectors, fully heated inner glass panes integrated in the full-sight glass door with 2-point locking (compression door lock) Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1250 x 1450 x 750\u00a0mm (d less 32 mm for fan - Peltier) Volume 1360\u00a0l Max. number of internals 28 Max. loading of chamber 250\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1435 x 1913 x 905\u00a0mm (d +56mm door handle & +111mm Peltier element) Installation on lockable castors, adjustable in height Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp1400ecoplus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T13:19:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"464\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/\",\"name\":\"Peltier-cooled incubator IPP1400ecoplus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1\",\"datePublished\":\"2021-11-16T13:01:47+00:00\",\"dateModified\":\"2021-11-16T13:19:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1\",\"width\":480,\"height\":464,\"caption\":\"Peltier-cooled incubator IPP1400ecoplus\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP1400ecoplus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP1400ecoplus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp1400ecoplus\/","og_locale":"es_ES","og_type":"article","og_title":"Peltier-cooled incubator IPP1400ecoplus","og_description":"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter Autodiagnostic system for fault analysis Heating concept Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Works calibration certificate for +25 \u00b0C and +40 \u00b0C Internals 4 stainless steel grid(s), electropolished Door Stainless steel doors with glass sectors, fully heated inner glass panes integrated in the full-sight glass door with 2-point locking (compression door lock) Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 1250 x 1450 x 750\u00a0mm (d less 32 mm for fan - Peltier) Volume 1360\u00a0l Max. number of internals 28 Max. loading of chamber 250\u00a0kg Max. loading per internal 30 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 1435 x 1913 x 905\u00a0mm (d +56mm door handle & +111mm Peltier element) Installation on lockable castors, adjustable in height Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1300\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp1400ecoplus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T13:19:05+00:00","og_image":[{"width":480,"height":464,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/","name":"Peltier-cooled incubator IPP1400ecoplus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1","datePublished":"2021-11-16T13:01:47+00:00","dateModified":"2021-11-16T13:19:05+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP1400ecoplus.png?fit=480%2C464&ssl=1","width":480,"height":464,"caption":"Peltier-cooled incubator IPP1400ecoplus"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp1400ecoplus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP1400ecoplus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product\/6974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media\/6975"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media?parent=6974"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_cat?post=6974"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_tag?post=6974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}