{"id":6954,"date":"2021-11-16T12:24:52","date_gmt":"2021-11-16T12:24:52","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6954"},"modified":"2021-11-16T12:27:07","modified_gmt":"2021-11-16T12:27:07","slug":"peltier-cooled-incubator-ipp260ecoplus","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp260ecoplus\/","title":{"rendered":"Incubadora refrigerada por Peltier IPP260ecoplus"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"

Temperatura<\/h4>\n\n\n\n\n\n\n\n
Ajuste del rango de temperatura<\/th>\n0 hasta +70 \u00b0 C<\/td>\n<\/tr>\n
Rango de temperatura de trabajo<\/th>\ncon luz: +10 a +40 \u00b0 C<\/td>\n<\/tr>\n
Rango de temperatura de trabajo<\/th>\nsin luz: de 0 (al menos 20 por debajo de la temperatura ambiente) a + 70 \u00b0 C<\/td>\n<\/tr>\n
Ajuste de la temperatura de precisi\u00f3n<\/th>\n0,1 \u00b0 C<\/td>\n<\/tr>\n
Sensor de temperatura<\/th>\n2 sensores Pt100 DIN Clase A en circuito de 4 hilos para monitoreo mutuo, asumiendo funciones en caso de error<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Tecnolog\u00eda de control<\/h4>\n\n\n\n\n\n\n\n\n\n
ControlCOCKPIT<\/th>\nTwinDISPLAY. Controlador de microprocesador PID digital multifuncional adaptativo con 2 pantallas TFT en color de alta definici\u00f3n.<\/td>\n<\/tr>\n
Configuraci\u00f3n de idioma<\/th>\nAlem\u00e1n, ingl\u00e9s, espa\u00f1ol, franc\u00e9s, polaco, checo, h\u00fangaro<\/td>\n<\/tr>\n
Temporizador<\/th>\nContador de retroceso digital con ajuste de tiempo objetivo, ajustable de 1 minuto a 99 d\u00edas<\/td>\n<\/tr>\n
Funci\u00f3n HeatBALANCE<\/th>\nAdaptando la distribuci\u00f3n del rendimiento de calefacci\u00f3n del circuito de calefacci\u00f3n superior e inferior de -50 % a +50 %<\/td>\n<\/tr>\n
Funci\u00f3n SetpointWAIT<\/th>\nel tiempo de proceso no comienza hasta que se alcanza la temperatura establecida<\/td>\n<\/tr>\n
Calibraci\u00f3n<\/th>\ntres valores de temperatura libremente seleccionables<\/td>\n<\/tr>\n
par\u00e1metros ajustables<\/th>\ntemperatura (Celsius o Fahrenheit), tiempo del programa, zonas horarias, horario de verano \/ invierno<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Ventilaci\u00f3n<\/h4>\n\n\n\n
Convecci\u00f3n<\/th>\nventilaci\u00f3n forzada por ventilador Peltier<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Comunicaci\u00f3n<\/h4>\n\n\n\n\n
Documentaci\u00f3n<\/th>\nprograma almacenado en caso de corte de energ\u00eda<\/td>\n<\/tr>\n
Programaci\u00f3n<\/th>\nSoftware AtmoCONTROL en una memoria USB para programar, administrar y transferir programas a trav\u00e9s de la interfaz Ethernet o el puerto USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Seguridad<\/h4>\n\n\n\n\n\n\n
Control de temperatura<\/th>\nMonitor de temperatura excesiva y baja TWW, clase de protecci\u00f3n 3.3 o limitador de temperatura ajustable TWB, clase de protecci\u00f3n 2, seleccionable en pantalla<\/td>\n<\/tr>\n
Auto SEGURIDAD<\/th>\nprotecci\u00f3n contra sobretemperatura y subtemperatura integrada adicionalmente "ASF", que sigue autom\u00e1ticamente el valor de consigna en un rango de tolerancia preestablecido, alarma en caso de sobretemperatura o subtemperatura, la funci\u00f3n de calefacci\u00f3n se desconecta en caso de sobretemperatura, la funci\u00f3n de refrigeraci\u00f3n en caso de subtemperatura<\/td>\n<\/tr>\n
Sistema de autodiagn\u00f3stico<\/th>\npara an\u00e1lisis de fallas<\/td>\n<\/tr>\n
Alarma<\/th>\nvisual y ac\u00fastico<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Concepto de calefacci\u00f3n<\/h4>\n\n\n\n\n
Peltier<\/th>\nDistribuci\u00f3n del rendimiento de calefacci\u00f3n y refrigeraci\u00f3n mediante control individual de los elementos Peltier en la fila superior e inferior<\/td>\n<\/tr>\n
Peltier<\/th>\nSistema de calefacci\u00f3n \/ refrigeraci\u00f3n Peltier de ahorro de energ\u00eda integrado en la parte trasera (principio de bomba de calor)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Equipamiento estandar<\/h4>\n\n\n\n\n\n\n
Puerta<\/th>\npuerta de acero inoxidable totalmente aislada con bloqueo de 2 puntos (bloqueo de puerta de compresi\u00f3n)<\/td>\n<\/tr>\n
Internos<\/th>\n2 rejillas de acero inoxidable, electropulidas<\/td>\n<\/tr>\n
Certificado de calibraci\u00f3n de obra<\/th>\npara + 10 \u00b0 C y + 37 \u00b0 C<\/td>\n<\/tr>\n
Puerta<\/th>\npuerta de vidrio interior<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Interior de acero inoxidable<\/h4>\n\n\n\n\n\n\n\n
Dimensiones<\/th>\nw(A)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 640 x 800 x 500 mm (d menos 32 mm para ventilador - Peltier)<\/td>\n<\/tr>\n
Volumen<\/th>\n256 litros<\/td>\n<\/tr>\n
Max. n\u00famero de internos<\/th>\n9<\/td>\n<\/tr>\n
Max. carga de la c\u00e1mara<\/th>\n200 kilogramos<\/td>\n<\/tr>\n
Max. cargando por interno<\/th>\n20 kilogramos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Carcasa de acero inoxidable con textura<\/h4>\n\n\n\n\n
Dimensiones<\/th>\nw(D)<\/sub>\u00a0xh(MI)<\/sub>\u00a0xd(F)<\/sub>: 824 x 1183 x 655 mm (d + manija de puerta de 56 mm y elemento Peltier de + 111 mm)<\/td>\n<\/tr>\n
Alojamiento<\/th>\ntrasero de acero cincado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Datos el\u00e9ctricos<\/h4>\n\n\n\n\n
Voltaje Carga el\u00e9ctrica<\/th>\n230 V, 50\/60 Hz
\naprox. 600 W<\/td>\n<\/tr>\n
Voltaje Carga el\u00e9ctrica<\/th>\n115 V, 50\/60 Hz
\naprox. 600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Condiciones ambientales<\/h4>\n\n\n\n\n\n\n\n\n
Configurar<\/th>\nLa distancia entre la pared y la parte trasera del aparato debe ser de al menos 15 cm. El espacio libre desde el techo no debe ser inferior a 20 cm y el espacio libre lateral desde las paredes o los electrodom\u00e9sticos cercanos no debe ser inferior a 5 cm.<\/td>\n<\/tr>\n
Temperatura ambiente<\/th>\n16 \u00baC a 40 \u00baC<\/td>\n<\/tr>\n
Humedad rh<\/th>\nm\u00e1x. 70 %, sin condensaci\u00f3n<\/td>\n<\/tr>\n
Altitud de instalaci\u00f3n<\/th>\nm\u00e1x. 2000 m sobre el nivel del mar<\/td>\n<\/tr>\n
Categor\u00eda de sobrevoltaje<\/th>\nII<\/td>\n<\/tr>\n
Grado de contaminaci\u00f3n<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":6955,"template":"","meta":{"nf_dc_page":""},"product_cat":[91],"product_tag":[],"yoast_head":"\nPeltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp260ecoplus\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peltier-cooled incubator IPP260ecoplus\" \/>\n<meta property=\"og:description\" content=\"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 32 mm for fan - Peltier) Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 200\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 655\u00a0mm (d +56mm door handle & +111mm Peltier element) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp260ecoplus\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T12:27:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP260ecoplus.png?fit=480%2C419&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"419\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\",\"name\":\"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"datePublished\":\"2021-11-16T12:24:52+00:00\",\"dateModified\":\"2021-11-16T12:27:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Peltier-cooled incubator IPP260ecoplus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/twitter.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp260ecoplus\/","og_locale":"es_ES","og_type":"article","og_title":"Peltier-cooled incubator IPP260ecoplus","og_description":"Temperature Setting temperature range 0 to +70 \u00b0C Working temperature range with light: +10 to +40 \u00b0C Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70\u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE adapting the distribution of the heating performance of the upper and lower heating circuit from -50\u00a0% to +50\u00a0% Function SetpointWAIT the process time does not start until the set temperature is reached Calibration three freely selectable temperature values adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime\/wintertime Ventilation Convection forced ventilation by Peltier fan Communication Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety Temperature control over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system for fault analysis Alarm visual and acoustic Heating concept Peltier Heating and cooling performance distribution by individual control of the Peltier elements in the upper and lower row Peltier energy-saving Peltier heating-\/cooling system integrated in the rear (heat pump principle) Standard equipment Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 stainless steel grid(s), electropolished Works calibration certificate for +10\u00b0C and +37\u00b0C Door inner glass door Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 640 x 800 x 500\u00a0mm (d less 32 mm for fan - Peltier) Volume 256\u00a0l Max. number of internals 9 Max. loading of chamber 200\u00a0kg Max. loading per internal 20 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 824 x 1183 x 655\u00a0mm (d +56mm door handle & +111mm Peltier element) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 600\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 16 \u00baC to 40 \u00baC Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2","og_url":"https:\/\/eastwings-diagnostics.com\/es\/producto\/peltier-cooled-incubator-ipp260ecoplus\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T12:27:07+00:00","og_image":[{"width":480,"height":419,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/Peltier-cooled-incubator-IPP260ecoplus.png?fit=480%2C419&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/","url":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/","name":"Peltier-cooled incubator IPP260ecoplus - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"datePublished":"2021-11-16T12:24:52+00:00","dateModified":"2021-11-16T12:27:07+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/peltier-cooled-incubator-ipp260ecoplus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"Peltier-cooled incubator IPP260ecoplus"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/twitter.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product\/6954"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media\/6955"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media?parent=6954"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_cat?post=6954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_tag?post=6954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}