{"id":6941,"date":"2021-11-16T11:08:54","date_gmt":"2021-11-16T11:08:54","guid":{"rendered":"https:\/\/eastwings-diagnostics.com\/?post_type=product&p=6941"},"modified":"2021-11-16T11:10:29","modified_gmt":"2021-11-16T11:10:29","slug":"co2-incubator-ico240","status":"publish","type":"product","link":"https:\/\/eastwings-diagnostics.com\/es\/producto\/co2-incubator-ico240\/","title":{"rendered":"Incubadora de CO2 ICO240"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"
\n

Temperatura<\/h4>\n\n\n\n\n\n\n\n\n
Rango de temperatura de trabajo<\/th>\n5 \u00b0 C por encima de la temperatura ambiente hasta +50 \u00b0 C
\nPrograma de esterilizaci\u00f3n est\u00e1ndar: 60 minutos a 180 \u00b0 C (sin quitar los sensores)<\/td>\n<\/tr>\n
Ajuste del rango de temperatura<\/th>\n+18 hasta +50 \u00b0 C<\/td>\n<\/tr>\n
Ajuste de la temperatura de precisi\u00f3n<\/th>\n0,1 \u00b0 C<\/td>\n<\/tr>\n
Sensor de temperatura<\/th>\n2 sensores Pt100 DIN Clase A en circuito de 4 hilos para monitoreo mutuo, asumiendo funciones en caso de error<\/td>\n<\/tr>\n
Variaci\u00f3n de temperatura en la c\u00e1mara<\/th>\na + 37 \u00b0 C +\/- 0,3 K<\/td>\n<\/tr>\n
Fluctuaciones de temperatura con el tiempo<\/th>\na 37 \u00b0 C +\/- 0,1 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Humedad<\/h4>\n\n\n\n\n\n
Control de humedad (est\u00e1ndar)<\/th>\nLimitaci\u00f3n de la humedad gracias a un elemento Peltier; cuando el plato de agua est\u00e1 lleno e insertado, el elemento Peltier limita el valor de la humedad relativa en el interior a 93 % rh +\/- 2.5 %<\/td>\n<\/tr>\n
Ajuste de la humedad de precisi\u00f3n<\/th>\n0.5 % derecho<\/td>\n<\/tr>\n
Rango de ajuste de control de humedad activo (con opci\u00f3n K7)<\/th>\n40 a 97 % dcha. Y dcha.-Off<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Control de componentes est\u00e1ndar<\/h4>\n\n\n\n\n\n\n\n\n
CO2<\/sub>\u00a0control<\/th>\nCO electr\u00f3nico digital2<\/sub>\u00a0control con sistema NDIR de doble haz, con sistema de autodiagn\u00f3stico e indicaci\u00f3n ac\u00fastica de fallas, compensaci\u00f3n de presi\u00f3n barom\u00e9trica<\/td>\n<\/tr>\n
Rango de ajuste CO2<\/sub><\/th>\n0 a 20 % CO2<\/sub><\/td>\n<\/tr>\n
Ajuste de precisi\u00f3n CO2<\/sub><\/th>\n0,1%<\/td>\n<\/tr>\n
Variaci\u00f3n en el tiempo CO2<\/sub><\/th>\n+\/- 0,2 % CO2<\/sub><\/td>\n<\/tr>\n
Rango de ajuste O2<\/sub><\/th>\n1 hasta 20 % O2<\/sub><\/td>\n<\/tr>\n
Ajuste de precisi\u00f3n O2<\/sub><\/th>\n0,1 % O2<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Tecnolog\u00eda de control<\/h4>\n\n\n\n\n\n\n
ControlCOCKPIT<\/th>\nTwinDISPLAY. Controlador de microprocesador PID digital multifuncional adaptativo con 2 pantallas TFT en color de alta definici\u00f3n.<\/td>\n<\/tr>\n
Configuraci\u00f3n de idioma<\/th>\nAlem\u00e1n, ingl\u00e9s, espa\u00f1ol, franc\u00e9s, polaco, checo, h\u00fangaro<\/td>\n<\/tr>\n
Funci\u00f3n SetpointWAIT<\/th>\nel tiempo de proceso no comienza hasta que se alcanza la temperatura establecida<\/td>\n<\/tr>\n
Par\u00e1metros ajustables<\/th>\ntemperatura (Celsius o Fahrenheit), CO2<\/sub>, horario del programa, zonas horarias, horario de verano \/ invierno<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Comunicaci\u00f3n<\/h4>\n\n\n\n\n\n
Interfaz<\/th>\nLAN Ethernet, USB<\/td>\n<\/tr>\n
Documentaci\u00f3n<\/th>\nprograma almacenado en caso de corte de energ\u00eda<\/td>\n<\/tr>\n
Programaci\u00f3n<\/th>\nSoftware AtmoCONTROL en una memoria USB para programar, administrar y transferir programas a trav\u00e9s de la interfaz Ethernet o el puerto USB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Seguridad<\/h4>\n\n\n\n\n\n
Auto SEGURIDAD<\/th>\nprotecci\u00f3n contra sobretemperatura y subtemperatura integrada adicionalmente "ASF", que sigue autom\u00e1ticamente el valor de consigna en un rango de tolerancia preestablecido, alarma en caso de sobretemperatura o subtemperatura, la funci\u00f3n de calefacci\u00f3n se desconecta en caso de sobretemperatura, la funci\u00f3n de refrigeraci\u00f3n en caso de subtemperatura<\/td>\n<\/tr>\n
Sistema de autodiagn\u00f3stico<\/th>\ndiagn\u00f3stico integral de fallas para temperatura y CO2<\/sub><\/td>\n<\/tr>\n
Alarma<\/th>\nvisual y ac\u00fastico<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Concepto de calefacci\u00f3n<\/h4>\n\n\n\n
6 lados<\/th>\nsistema de calefacci\u00f3n multifunci\u00f3n de gran superficie en los cuatro lados con puerta adicional y calefacci\u00f3n trasera para evitar la condensaci\u00f3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n
\n

Equipamiento estandar<\/h4>\n\n\n\n\n\n\n\n\n
Accesorios estandar<\/th>\nFiltro de membrana (para eliminar impurezas y contaminantes, todos los gases entrantes pasan a trav\u00e9s de un filtro de membrana antes de llegar a la c\u00e1mara)<\/td>\n<\/tr>\n
Puerta<\/th>\npuerta de acero inoxidable totalmente aislada con bloqueo de 2 puntos (bloqueo de puerta de compresi\u00f3n)<\/td>\n<\/tr>\n
Internos<\/th>\n2 baldas \/ baldas de acero inoxidable perforado<\/td>\n<\/tr>\n
Certificado de calibraci\u00f3n de obras<\/th>\nincl. certificado de calibraci\u00f3n de f\u00e1brica (centro de la c\u00e1mara del punto de medici\u00f3n) a + 37 \u00b0 C, 5 % CO2<\/sub>\u00a0para unidades est\u00e1ndar<\/td>\n<\/tr>\n
Internos<\/th>\n1 plato de agua de acero inoxidable<\/td>\n<\/tr>\n
Puerta<\/th>\npuerta interior de cristal con abertura (8 mm \u00d8) para toma de muestra de gas<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Interior de acero inoxidable<\/h4>\n\n\n\n\n\n\n\n\n
Dimensiones<\/th>\nw(A)<\/sub>\u00a0xh(B)<\/sub>\u00a0xd(C)<\/sub>: 600 x 810 x 500 mm (d menos 35 mm para el ventilador)<\/td>\n<\/tr>\n
Interior<\/th>\nmaterial 1.4301 (ASTM 304), resistente a la corrosi\u00f3n<\/td>\n<\/tr>\n
Volumen<\/th>\n241 litros<\/td>\n<\/tr>\n
Max. n\u00famero de internos<\/th>\n12<\/td>\n<\/tr>\n
Max. carga de la c\u00e1mara<\/th>\n140 kilogramos<\/td>\n<\/tr>\n
Max. cargando por interno<\/th>\n15 kilogramos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Carcasa de acero inoxidable con textura<\/h4>\n\n\n\n\n
Dimensiones<\/th>\nw(D)<\/sub>\u00a0xh(MI)<\/sub>\u00a0xd(F)<\/sub>: 759 x 1180 x 691 mm (d + manija de puerta de 56 mm)<\/td>\n<\/tr>\n
Alojamiento<\/th>\ntrasero de acero cincado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Datos el\u00e9ctricos<\/h4>\n\n\n\n\n
Voltaje Carga el\u00e9ctrica<\/th>\n230 V, 50\/60 Hz
\naprox. 1650 W<\/td>\n<\/tr>\n
Voltaje Carga el\u00e9ctrica<\/th>\n115 V, 50\/60 Hz
\naprox. 1650 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Condiciones ambientales<\/h4>\n\n\n\n\n\n\n\n\n
Configurar<\/th>\nLa distancia entre la pared y la parte trasera del aparato debe ser de al menos 15 cm. El espacio libre desde el techo no debe ser inferior a 20 cm y el espacio libre lateral desde las paredes o los electrodom\u00e9sticos cercanos no debe ser inferior a 5 cm.<\/td>\n<\/tr>\n
Temperatura ambiente<\/th>\n10 \u00b0 C hasta 35 \u00b0 C<\/td>\n<\/tr>\n
Humedad rh<\/th>\nm\u00e1x. 70 %, sin condensaci\u00f3n<\/td>\n<\/tr>\n
Altitud de instalaci\u00f3n<\/th>\nm\u00e1x. 2000 m sobre el nivel del mar<\/td>\n<\/tr>\n
Categor\u00eda de sobrevoltaje<\/th>\nII<\/td>\n<\/tr>\n
Grado de contaminaci\u00f3n<\/th>\n2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

Datos de embalaje \/ env\u00edo<\/h4>\n\n\n\n\n\n\n\n\n\n
Informaci\u00f3n de transporte<\/th>\nLos aparatos deben transportarse en posici\u00f3n vertical<\/td>\n<\/tr>\n
N\u00famero de arancel aduanero<\/th>\n8419 8998<\/td>\n<\/tr>\n
Pa\u00eds de origen<\/th>\nRep\u00fablica Federal de Alemania<\/td>\n<\/tr>\n
WEEE-Reg.-No.<\/th>\nDE 66812464<\/td>\n<\/tr>\n
Dimensiones aprox. Incl. caja de cart\u00f3n<\/th>\nancho x alto x fondo: 840 x 1360 x 900 mm<\/td>\n<\/tr>\n
Peso neto<\/th>\naprox. 110 kilogramos<\/td>\n<\/tr>\n
Caja de cart\u00f3n de peso bruto<\/th>\naprox. 145 kilogramos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"featured_media":6942,"template":"","meta":{"nf_dc_page":""},"product_cat":[90],"product_tag":[],"yoast_head":"\nCO2 incubator ICO240 - Eastwings Diagnostics Ltd<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CO2 incubator ICO240\" \/>\n<meta property=\"og:description\" content=\"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eastwings-diagnostics.com\/es\/producto\/co2-incubator-ico240\/\" \/>\n<meta property=\"og:site_name\" content=\"Eastwings Diagnostics Ltd\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-16T11:10:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"424\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eastwings3\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\",\"name\":\"CO2 incubator ICO240 - Eastwings Diagnostics Ltd\",\"isPartOf\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"datePublished\":\"2021-11-16T11:08:54+00:00\",\"dateModified\":\"2021-11-16T11:10:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1\",\"width\":480,\"height\":424,\"caption\":\"CO2 incubator ICO240\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/eastwings-diagnostics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/eastwings-diagnostics.com\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"CO2 incubator ICO240\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#website\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"name\":\"Eastwings Diagnostics Ltd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#organization\",\"name\":\"Eastwings Diagnostics LTD\",\"url\":\"https:\/\/eastwings-diagnostics.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"contentUrl\":\"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png\",\"width\":512,\"height\":120,\"caption\":\"Eastwings Diagnostics LTD\"},\"image\":{\"@id\":\"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/eastwings3\",\"http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eastwings-diagnostics.com\/es\/producto\/co2-incubator-ico240\/","og_locale":"es_ES","og_type":"article","og_title":"CO2 incubator ICO240","og_description":"Temperature Working-temperature range 5 \u00b0C above ambient temperature up to +50 \u00b0C Standard sterilisation programme: 60 minutes at 180\u00b0C (without removing the sensors) Setting temperature range +18 to +50 \u00b0C Setting accuracy temperature 0.1 \u00b0C Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Temperature variation in chamber at + 37 \u00b0C +\/- 0.3 K Temperature fluctuations with time at 37 \u00b0C +\/- 0.1 K Humidity Humidity control (standard) Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93\u00a0%\u00a0rh +\/- 2.5\u00a0% Setting accuracy humidity 0.5\u00a0% rh Setting range active humidity control (with option K7) 40 to 97\u00a0%\u00a0rh and rh-Off Control of standard components CO2\u00a0control Digital electronic CO2\u00a0control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation Adjustment range CO2 0 to 20\u00a0% CO2 Setting accuracy CO2 0,1% Variation in time CO2 +\/- 0.2\u00a0% CO2 Adjustment range O2 1 to 20\u00a0% O2 Setting accuracy O2 0.1\u00a0% O2 Control technology ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting German, English, Spanish, French, Polish, Czech, Hungarian Function SetpointWAIT the process time does not start until the set temperature is reached Adjustable parameters temperature (Celsius or Fahrenheit), CO2, programme time, time zones, summertime\/wintertime Communication Interface Ethernet LAN, USB Documentation programme stored in case of power failure Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port Safety AutoSAFETY additionally integrated over- and undertemperature protection \"ASF\", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature Autodiagnostic system integral fault diagnostics for temperature and CO2 Alarm visual and acoustic Heating concept 6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation Standard equipment Standard accessories Membrane filter (in order to remove impurities and pollutants, all incoming gases pass through a membrane filter before they reach the chamber) Door fully insulated stainless steel door with 2-point locking (compression door lock) Internals 2 perforated stainless steel shelf\/shelves Works calibation certificate incl. works calibration certificate (measuring point chamber centre) at +37\u00b0C, 5\u00a0% CO2\u00a0for standard units Internals 1 stainless steel water dish Door inner glass door with opening (8\u00a0mm \u00d8) to take gas sample Stainless steel interior Dimensions w(A)\u00a0x h(B)\u00a0x d(C): 600 x 810 x 500\u00a0mm (d less 35 mm for fan) Interior material 1.4301 (ASTM 304), corrosion resistant Volume 241\u00a0l Max. number of internals 12 Max. loading of chamber 140\u00a0kg Max. loading per internal 15 kg Textured stainless steel casing Dimensions w(D)\u00a0x h(E)\u00a0x d(F): 759 x 1180 x 691\u00a0mm (d +56mm door handle) Housing rear zinc-plated steel Electrical data Voltage Electrical load 230\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Voltage Electrical load 115\u00a0V, 50\/60\u00a0Hz approx. 1650\u00a0W Ambient conditions Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. Ambient temperature 10 \u00b0C to 35 \u00b0C Humidity rh max. 70 %, non-condensing Altitude of installation max. 2,000 m above sea level Overvoltage category II Pollution degree 2 Packing\/shipping data Transport information The appliances must be transported upright Customs tariff number 8419 8998 Country of origin Federal Republic of Germany WEEE-Reg.-No. DE 66812464 Dimensions approx incl. carton w x h x d: 840 x 1360 x 900\u00a0mm Net weight approx. 110\u00a0kg Gross weight carton approx. 145\u00a0kg","og_url":"https:\/\/eastwings-diagnostics.com\/es\/producto\/co2-incubator-ico240\/","og_site_name":"Eastwings Diagnostics Ltd","article_modified_time":"2021-11-16T11:10:29+00:00","og_image":[{"width":480,"height":424,"url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@eastwings3","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","url":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/","name":"CO2 incubator ICO240 - Eastwings Diagnostics Ltd","isPartOf":{"@id":"https:\/\/eastwings-diagnostics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","datePublished":"2021-11-16T11:08:54+00:00","dateModified":"2021-11-16T11:10:29+00:00","breadcrumb":{"@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#primaryimage","url":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","contentUrl":"https:\/\/i0.wp.com\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/CO2-incubator-ICO240.png?fit=480%2C424&ssl=1","width":480,"height":424,"caption":"CO2 incubator ICO240"},{"@type":"BreadcrumbList","@id":"https:\/\/eastwings-diagnostics.com\/product\/co2-incubator-ico240\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eastwings-diagnostics.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/eastwings-diagnostics.com\/products\/"},{"@type":"ListItem","position":3,"name":"CO2 incubator ICO240"}]},{"@type":"WebSite","@id":"https:\/\/eastwings-diagnostics.com\/#website","url":"https:\/\/eastwings-diagnostics.com\/","name":"Eastwings Diagnostics Ltd","description":"","publisher":{"@id":"https:\/\/eastwings-diagnostics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eastwings-diagnostics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/eastwings-diagnostics.com\/#organization","name":"Eastwings Diagnostics LTD","url":"https:\/\/eastwings-diagnostics.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/","url":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","contentUrl":"https:\/\/eastwings-diagnostics.com\/wp-content\/uploads\/2021\/11\/eastwingss-diaa.png","width":512,"height":120,"caption":"Eastwings Diagnostics LTD"},"image":{"@id":"https:\/\/eastwings-diagnostics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/eastwings3","http:\/\/www.linkedin.com\/in\/eastwings-diagnostics-213031226"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product\/6941"}],"collection":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media\/6942"}],"wp:attachment":[{"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/media?parent=6941"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_cat?post=6941"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/eastwings-diagnostics.com\/es\/wp-json\/wp\/v2\/product_tag?post=6941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}